Data Sheet
Timing in Particle-Sensing Mode Using 1 LED
The internal FIFO stores up to 32 samples, so that the
system processor does not need to read the data after
every sample (Figure 5).
Figure 5. Timing for Data Acquisition and Communication When in Particle-Sensing Mode Using 1 LED
Table 16. Events Sequence for Figure 5 in Particle-Sensing Mode Using 1 LED
EVENT DESCRIPTION COMMENTS
1 Enter Particle-Sensing Mode
I
2
C Write Command sets MODE[2:0] = 0x02. Mask the DATA_RDY
Interrupt.
2 FIFO is Almost Full, Interrupt Generated Interrupt is generated when the FIFO has only one empty space left.
3 FIFO Data is Read, Interrupt Cleared
4 Next Sample is Stored
New sample is stored at the new read pointer location. Effectively, it is
now the rst sample in the FIFO.
INT
I
2
C Bus
LED
OUTPUTS
IR
~
~
~
SAMPLE #1 SAMPLE #2 SAMPLE #3 SAMPLE #30 SAMPLE #31
1 2 3 4
15ms TO 300ms
IR IR IR IR IR IR
www.maximintegrated.com
Maxim Integrated
│
28
MAX30105 High-Sensitivity Optical Sensor
for Smoke Detection Applications