Datasheet-2

a-Si TFT LCD Single Chip Driver
132RGBx162 Resolution and 262K color
ILI9163C
Page 80 of 200
Version:0.09
RESX Pulse Action
Shorten than 5s Reset Rejected
Longer than 10s Reset
Between 5 s and 10s Reset starts (It depends on voltage and temperature condtion.)
2. During the resetting period, the display will be blanked (The display is entering blanking sequence, which
maximum time is 120 ms, when Reset Starts in Sleep Out –mode. The display remains the blank state in
Sleep In –mode) and then return to Default condition for Hardware Reset.
3. During Reset Complete Time, ID2 and VCOMOF value in OTP will be latched to internal register during
this period. This loading is done every time when there is H/W reset complete time (tREST) within 5ms
after a rising edge of RESX.
4. Spike Rejection also applies during a valid reset pulse as shown below:
5. It is necessary to wait 5msec after releasing RESX before sending commands. Also Sleep Out command
cannot be sent for 120msec.