Datasheet-2
a-Si TFT LCD Single Chip Driver
132RGBx162 Resolution and 262K color
ILI9163C
Page 104 of 200
Version:0.09
14.2.12 Sleep Out (11h)
11H SLPOUT (Sleep Out)
D/CX
RDX
WRX
D17-8
D7 D6 D5 D4 D3 D2 D1 D0 HEX
Command
0 1 x 0 0 0 1 0 0 0 1 11h
Parameter
No Parameter
Descriptio
n
This command turns off sleep mode.
In this mode e.g. the DC/DC converter is enabled, Internal oscillator is started, and panel scanning is started.
Restriction
This command has no effect when module is already in sleep out mode. Sleep
Out Mode can only be left by the Sleep In Command (10h).
It will be necessary to wait 5 msec before sending next command; this is to allow time for the clock circuits to stabilize.
The display module loads all display supplier’s factory default values to the registers during this 120 msec and there
cannot be any abnormal visual effect on the display image if factory default and register values are same when this load is
done and when the display module is already Sleep Out –mode.
The display module is doing self-diagnostic functions during this 5msec. It will be necessary to wait 120msec after
sending Sleep In command (when in Sleep Out mode) before Sleep Out command can be sent.
This command has no effect when module is already in sleep out mode.
Sleep Out Mode can only be left by HW Reset, Software Reset (01h), Sleep In (10h), or a NMI event trigger.
Register
Availability
Status Availability
Normal Mode On, Idle Mode Off, Sleep Out
Yes
Normal Mode On, Idle Mode On, Sleep Out
Yes
Partial Mode On, Idle Mode Off, Sleep Out
Yes
Partial Mode On, Idle Mode On, Sleep Out
Yes
Sleep In Yes
Default
Status Default Value
Power On Sequence Sleep In Mode
SW Reset Sleep In Mode
HW Reset Sleep In Mode
Flow Chart
It takes 120msec to become Sleep Out mode after SLPOUT command issued.