Datasheet

NEO-M9N-Data sheet
Parameter Symbol Min Typical Max Units Condition
VCC_RF output current ICC_RF 50 mA
Receiver chain noise figure
6
NFtot 3.5 dB
Operating temperature Topr -40 +25 85 °C
Table 11: Operating conditions
Operation beyond the specified operating conditions can affect device reliability.
4.3 Indicative power requirements
Table 12 lists examples of the total system supply current including RF and baseband section for
a possible application.
Values in Table 12 are provided for customer information only, as an example of typical
current requirements. Values are characterized on samples with a commanded cold start.
Actual power requirements can vary depending on FW version used, external circuitry,
number of SVs tracked, signal strength, type and time of start, duration, and conditions of
test.
Symbol Parameter Conditions GPS+GLO+GAL+BDS GPS+GLO GPS Unit
I
PEAK
Peak current Acquisition 100 100 100 mA
I
VCC
7
VCC current Acquisition 50 42 37 mA
Tracking
(Continuous mode)
36 31 27 mA
Tracking
(Power save mode)
20 20 19 mA
Table 12: Currents to calculate the indicative power requirements
All values in Table 12 are measured at 25 °C ambient temperature. SBAS and QZSS is activated in
all measurements.
6
Only valid for the GPS
7
Simulated signal, current measured at 3.0 V
UBX-19014285 - R02
4 Electrical specification Page 11 of 21