Datasheet

Non-Isolated DC/DC Converter Specification
Model No.: WG8-36S1206
Shenzhen Wengao Electronic Co., Ltd reserves the copyright and right of final interpretation.
Typical Waveforms
Conditions: TA = 25°C (77°F), Vin = 12V, unless otherwise specified.
Figure 4, 25% - 50% load dynamic
Figure 5, 50% - 75% load dynamic
Figure 6, Output voltage established (Iout = 6A)
Figure 7, Output ripple & noise (Iout = 6A)
Feature Description
Remote On/Off (EN) (Optional)
Input Undervoltage Protection
Logic
Enable
Low level
(0 - 8Vdc)
High level
(8-38Vdc)
Left open
Positive
logic
Off
On
Off
The converter will shut down after the input voltage
drops below the under-voltage protection threshold for
shutdown. The converter will start to work again after
the input voltage reaches the input under voltage
protection threshold for startup. For the Hysteresis, see
the Protection characteristics.
Various circuits for driving the EN
Output Overcurrent Protection
The converter equipped with current limiting circuitry
can provide protection from an output overload or short
circuit condition. If the output current exceeds the
output overcurrent protection set point, the converter
enters hiccup mode. When the fault condition is
removed, the converter will automatically restart.
Simple control
Transistor control