Datasheet
Table Of Contents
58 / 66 W5500 Datasheet Version1.0.9
Electrical Specifications
5.1 Absolute Maximum Ratings
Symbol
Parameter
Rating
Unit
V
DD
DC Supply voltage
-0.5 to 4.6
V
V
IN
DC input voltage
-0.5 to 6
V
V
OUT
DC output voltage
-0.5 to 4.6
V
I
IN
DC input current
5
mA
T
OP
Operating temperature
-40 to +85
C
T
JMAX
Maximum junction temperature
125
C
T
STG
Storage temperature
-65 to +150
C
*COMMENT: Stressing the device beyond the ‘Absolute Maximum Ratings’ may cause
permanent damage.
5.2 Absolute Maximum Ratings (Electrical Sensitivity)
Electrostatic discharge (ESD)
Symbol
Parameter
Test Condition
Class
Maximum
value(1)
Unit
VESD(HBM)
Electrostatic discharge
voltage (human body
model)
TA = +25 °C
conforming to MIL-STD
883F Method 3015.7
2
2000
V
VESD(MM)
Electrostatic discharge
voltage (man machine
model)
TA = +25 °C
conforming to JEDEC
EIA/JESD22 A115-A
B
200
V
VESD(CDM)
Electrostatic discharge
voltage (charge device
model)
TA = +25 °C
conforming to JEDEC
JESD22 C101-C
III
500
V
Static latchup
Symbol
Parameter
Test Condition
Class
Maximum
value(1)
Unit
LU
Static latch-up class
TA = +25 °C conforming
to JESD78A
I
≥ ±200
mA