Datasheet

DG600F Coin Acceptor Technical Manual Version 1.0 - 06.2010
Page 20 of 21-
9. Common Faulties
9.1
9.19.1
9.1
Error C
Error CError C
Error Code(E1
ode(E1 ode(E1
ode(E1 -
--
- E7,EE)
E7,EE) E7,EE)
E7,EE)
Error code E1
It displays E1 after power on, it means that the first pair of sensor is out of order.
It displays E1 after deposit coin, it means that coin duration at the first pair of sensor is too
long.
Error code E2
It displays E2 after power on, it means that the first pair of sensor is out of order.
It displays E2 after deposit coin, it means that coin duration at the second pair of sensor is
too long.
Error code E3
It displays E3 after power on, it means that the first pair of sensor is out of order.
It displays E3 after deposit coin, it means that coin duration at the third pair of sensor is too
long.
Error code E4
It displays E4 after power on, it means that the first pair of sensor is out of order.
It displays E4 after deposit coin, it means that coin duration at collection gate is too long.
Error code E5
It displays E5 after power on, it means that the first pair of induction coil is out of order.
Error code E6
It displays E6 after power on, it means that the second pair of induction coil is out of order.
Error code E7
It displays E7 after power on, it means that button A or B is stuck.
Error code EE
It displays EE after deposit coin, it means that there are coins not collected in coin box.
9.2
9.29.2
9.2
C
CC
Coins
oins oins
oins A
AA
Are
re re
re Refused And Return
Refused And ReturnRefused And Return
Refused And Returned
eded
ed
Inhibiting port output level mode is selected incorrect, please refer to 6.4 to check if
switch SW4 is on the proper position; or check if the controlling electric level outputted
from machine meets requirements or not.
There isn't this coin parameters stored in coin acceptor, please refer to 7.5 to add new
coin parameters.
.