Atmel | SMART SAM D21 [DATASHEET]
Atmel-42181G–SAM-D21_Datasheet–09/2015
4 - In two ramp mode, two events will be generated per cycle, one on each ramp’s end.
EVCTRL.CNTSEL.END cannot be used to identify the end of a double ramp cycle. Errata
reference: 12224
Fix/Workaround:
None
5 - If an input event triggered STOP action is performed at the same time as the counter
overflows, the first pulse width of the subsequent counter start can be altered with one
prescaled clock cycle. Errata reference: 12107
Fix/Workaround:
None
6 - When the RUNSTDBY bit is written after the TCC is enabled, the respective TCC APB bus
is stalled and the RUNDSTBY bit in the TCC CTRLA register is not enabled-protected. Errata
reference: 12477
Fix/Workaround:
None.
7 - TCC fault filtering on inverted fault is not working. Errata reference: 12512
Fix/Workaround:
Use only non-inverted faults.
8 - When waking up from the STANDBY power save mode, the SYNCBUSY.CTRLB and
SYNCBUSY.STATUS bits may be locked to 1. Errata reference: 12227
Fix/Workaround:
After waking up from STANDBY power save mode, perform a software reset of the TCC if you are
using the SYNCBUSY.CTRLB and SYNCBUSY.STATUS bits
9 - When the Peripheral Access Controller (PAC) protection is enabled, writing to WAVE or
WAVEB registers will not cause a hardware exception. Errata reference: 11468
Fix/Workaround:
None
10 - If the MCx flag in the INTFLAG register is set when enabling the DMA, this will trigger an
immediate DMA transfer and overwrite the current buffered value in the TCC register. Errata
reference: 12155
Fix/Workaround:
None
39.1.4.10 PTC
1 - WCOMP interrupt flag is not stable. The WCOMP interrupt flag will not always be set as
described in the datasheet. Errata reference: 12860
Fix/Workaround: