Install Manual

15SPAN Drive Installation Manual Installation |
5. Rated current adjustment
On the left side of the circuit board, locate the current
selector switch, and set the switch to the appropriate
setting per the chart below. If installing with a SPAN Panel,
the current selector switch can be left at “0, and the
current rating can be set through the SPAN Installer App.
Current selector
switch position
Max current,
continuous
Circuit
breaker rating
0 Default
1 Reserved
2 16 A 20 A
3 20 A 25 A
4 24 A 30 A
5 28 A 35 A
6 32 A 40 A
7 36 A 45 A
8 40 A 50 A
9 48 A 60 A
CAUTION: Be sure to select a switch position that does not exceed your circuit breaker rating.
To reduce the risk of re, only connect your charger to a circuit with a branch circuit
overcurrent protection of 125% of the selected max amperage setting of the device in
accordance with ANSI/NFPA (US) C22.2 NO 280 13 (Canada).
0
1
2
3
4
5
6
7
8
9
Current
Selector
Switch