Install Manual
Table Of Contents
- CONTENTS
- ABOUT YOUR span panel
- Preparing to Install
- Installation
- Troubleshooting & SERVICING
- APPENDIX A: circuit breaker Compatibility
- The Span Panel is compatible with the following Homeline circuit breakers from Square D:
- The Span Panel is compatible with the following circuit breakers from Eaton:
- The Span Panel is compatible with the following circuit breakers from Siemens:
- The Span Panel is compatible with the following MP circuit breakers from Murray:
- APPENDIX B: Surge protective device compatability
Span 1-00800-xx Installation Manual (rev. 2022-01-28) 8
INSTALLATION
1. Mounting the Panel
Remove the Deadfront
● Using a flat screwdriver, loosen the single deadfront fastener screw and remove the deadfront cover.
Mount the Unit
● Ensure the wall space can accommodate the flush section without interference from pipes or conductors inside the wall space.
● Using a drill and level, mount the Span Panel enclosure on the wall, observing site and mechanical requirements, and
applicable building codes. Secure the unit at all 4 mounting points.
● When flush mounting, drill ¼” pilot holes, marked by interior markings of the panel. Install fasteners through the side walls to
secure the panel to the studs, as shown below.
Wall Mounting Points for Surface-Mount (left) and Flush-Mount (right)
WARNING: Risk of electric shock. If you are replacing an existing electrical panel, make sure power is turned off before
removing the old panel and when installing the Span Panel. Always make sure all electrical equipment is safely de-
energized before beginning work
CAUTION: The unit must be installed within 10 degrees of vertical, and level from side-to-side.