Install Manual

Span 1-00800-xx Installation Manual (rev. 2022-01-28) 20
Resetting the System
If it becomes necessary to restart the system use a small tool to press the Reset button, located below the communication terminals.
Hold the button for 10 full seconds before releasing.
Overriding the Grid Disconnect Relay
If it is necessary to manually reconnect your home to the grid, Span Support may direct you to operate the manual override in
the Span Panel.
To reconnect to the grid manually, peel away the protective label, insert a large flathead screwdriver, and turn
counterclockwise until you hear a click.
CAUTION: Do not remove the protective label or operate the manual override unless directed to do so by Span Support.
Improper operation of the manual override may damage the unit.
Adding, Removing, or Changing Branch Circuit Breakers
Branch circuit position numbers are labelled adjacent to the breaker. A specific space location can be associated with the physical circuit
position in the Span panel by viewing the space in either the Span Installer or Span Home app.
To add, remove, or change branch circuit breakers:
Follow instructions above in this manual to select, install, and wire circuit breakers.
Use the Span Installer app to make changes to the branch breakers, following on screen instructions.
Homeowners should be instructed to contact Span Support for any future branch breaker additions, removals, or changes.
CAUTION: To perform routine service or maintenance on circuits, confirm that the corresponding circuit breakers are
switched off. Powering down circuits using the Span internal relays should not be considered a suitable Off position for
servicing equipment.