User's Manual
SPECIFICATIONS
Ultraview
1050
Monitor
90369
Page
2
of
4
Tabular
—
Time
increments
of
1,
5,
10,
15,
or
30
minutes;
1,
1.5
or
3
hours
(1
hour
is
the
default)
Remote
View/Alarm
Watch
—
When
equipped
with
the
Ethernet
option,
the
1050
provides
a
waveform
display
from
a
remote
bedside
or
telemetry
patient
on
the
Ultraview
network
either
on
request
(Remote
View)
and/or
in
response
to
an
alarm
(Alarm
Watch);
the
1050
provides
a
waveform
display
from
up
to
32
selected
beds;
an
Ultraview
bedside
monitor
can
be
remotely
viewed
by
up
to
16
network
devices
simultaneously
(e.g.,
monitors,
workstations)
Display
—
Trace
Height: 1.65
in
(4.2
cm)
2.36
in
(6.0
cm)
Sweep
Speed:
A
variety
of
speeds
are
available
under
module
control
Ethernet
Communication
—
10BaseT
telephone-style
modular
connector
(RJ45)
provided
Wireless
Ethernet
Capability
—
Provides
2.4
GHz
frequency-hopping
spread-spectrum
communication;
the
wireless
Ethernet
will
send
one
to
five
waveforms
and
numeric
vital
signs
to
the
Ultraview
Care
Network
Color
TFT
Display
(TFT)
—
Resolution
—
640
by
480
pixels
Size
—
8.31
in
(21.12
cm)
wide
6.24
in
(15.84
cm)
high
Software
Updates
—
Software
updates
including
new
features
and
capabilities
are
easily
updated
over
the
network
Options
—
F
—
Ethernet
interface,
SDLC,
audio
I/O,
video,
alarm,
serial;
provides
noninteractive
bed-to-bed
communication
H—
Capnography,
Ethernet
interface,
SDLC,
audio
I/O,
video,
alarm,
serial
N
—
Vital
Signs
Calculations
O
—
Drug
Dose
Calculations
P—
Interactive
Network
Functions
—
Adds
interactive
remote
view
and
alarm
watch
capabilities
for
parameters
displayed
from
remote
bedsides
and
remote
functionality
for
all
trends
(requires
option
F
or
H)
Q—
Data
Shuttle
to
transfer
patient
information
to
another
monitor
R
—
Patient
Data
Logger
U
—
Dual
Channel
Internal
Recorder
Z
—
Wireless
Ethernet
Communication
04 —
Four
waveforms
05 —
Five
waveforms
06 —
Six
waveforms
ELECTRICAL
SPECIFICATIONS
Mains
Power
—
Line
voltage:
100-240
VAC;
Frequency:
50-60
Hz
Batteries
—
Both
sealed-lead
acid
(SLA)
and
Spacelabs
Medical
nickel
metal
hydride
(NiMH)
are
supported.
One
or
two
12
V
(2.30
Ah
SLA
or
2.45
Ah
NiMH)
batteries
may
be
used,
providing
up
to
2.0
hours
of
operation
(TFT
display)
for
up
to
300
charge/discharge
cycles
with
SLA
and
up
to
2.5
hours
of
operation
(TFT
display)
for
up
to
600
charge/
discharge
cycles
with
NiMH;
operating
time
is
dependent
on
configuration
and
usage;
1.5
hours
are
required
to
charge
batteries
to
100%
of
capacity
with
AC
connected
to
rear
panel
and
mains
switch
in
the
OFF
position,
3-hour
charge
time
required
with
the
mains
switch
in
the
ON
position
Power
Fail
Backup
—
Will
maintain
patient
data
for
a
minimum
of
three
minutes
Isolation
—
Chassis
leakage
current
not
greater
than
300
µA
(meets
AAMI,
UL2601-1,
CSA
#601.1
and
IEC
601-1
standards)
PHYSICAL
DIMENSIONS
Height:
8.3
in
(21.1
cm)
Depth:
6.2
in
(15.8
cm)
Width:
11.7
in
(29.7
cm)
Weight:
10.0
Ibs
(4.6
kg)
DUAL
CHANNEL
INTERNAL
RECORDER
—
Option
U
Printing
Method
—
Thermal
array
print
head
Resolution
—
Eight
dots
per
mm
vertical
and
32
dots
per
mm
horizontal
at
25mm
per
second
sweep
speed
Paper
—
Heat-sensitive
paper,
50mm
wide
x
30m
long,
available
in
a
roll
Traces
—
All
monitored
parameters,
including
waveforms
and
graphic
trends,
full
annotation
included
Frequency
Response
—
Determined
by
the
parameter
recorded
Chart
Speed
—
1.56,
3.12,
6.25,
12.5,
25
and
50mm
per
second
(depending
on
the
monitor
sweep
speed
selected)
Alarm
Record
—
Records
any
parameters
in
an
alarm
state
when
“Record
on
Alarm”
is
active
Auto
Run
—
20
seconds
or
duration
of
alarm
violation
(whichever
is
longer)