Instruction Manual
8. Carefully pull the in-line connectors apart to remove
the ceramic emier as shown in Fig. N. Note, when
reng, the connectors must be fully pushed
together and you should feel a dull click and the
sleeving should also be replaced back over the
connectors. Also take note of the emier wire
colours and match.
9. Working on a at surface, slide the ceramic emier
holding U-clip away from the ceramic emier raised
wiring boss as shown in Fig. P. Note. the sleeving
can be removed at this point before proceeding.
Remove the spring clip (note it’s orientaon as
shown in Fig Q) from the reector and li the
reector o the ceramic emier as shown in Fig. R.
10. Ret in reverse order and repeat for any other
ceramic emiers that need to be replaced.
5.2 Heater failure
In the event of heater failure, or for spare parts or
advice, please contact the manufacturer or your service
agent.
• Disconnect from the mains by removing the plug
from the main sockets before commencing any
maintenance procedure including cleaning.
• To ensure opmum heat eecveness, it is recom-
mended that that the guards are removed and the
reectors are wiped with a lint-free cloth should
the reectors show considerable signs of dust or
dirt.
The use of this symbol indicates
that this product may not be
treated as household waste. By
ensuring this product is disposed
of correctly, you will help prevent
potenal negave consequences
for the environment and human
health, which could otherwise be
caused by inappropriate waste
handling of this product.
For more detailed informaon about recycling of this
product, please contact your local council or your
household waste disposal service.
The manufacturer hereby conrms that the Eclipse
heaters comply with the harmonised standards and
spulaons quoted below:
EN 60335-2-30:2009+A11:12
EN 60335-1:2012
EN 62233:2008
LVD 2006/95/EC
EN 61000-3-2, EN 61000-3-3
EMC Direcve 2004/108/EC
WEEE & RoHS Direcves 2002/96/EC & 2002/95/EC
Fig. N
Fig. P
Fig. Q
Fig. R