Instruction Manual
The Eclipse range of heaters contain long-life ceram-
ic emiers which are highly ecient and durable. The
Eclipse heaters are designed for indoor use and outdoor
(under cover use) only.
future reference.
3.1 Dimensions
All Eclipse models are ed with 3m of supply cable and
a 3-pin plug. For permenent connecon it is unnecessary
to open the terminal wiring enclosure, in order to carry
out installaon of this product.
CAUTION: Please observe the minimum safe distance
between the heater body and any inammable surfaces.
CAUTION: Do not mount the heater on plasc sots and
fascia boards and ensure the mounng surface will
suitably withstand the radiant heat from the heater
body.
CAUTION: All installaons must be in accordance with
the latest electrical safety regulaons.
NOTE: When hard wiring, a large double pole switch with
a 3.0mm contact disconnecon should be ed.
NOTE: When installing the heater indoors it should be
connected to a suitable thermostat device.
NOTE: We recommend using a RCD where applicable.
The Eclipse heater should be wall mounted in a horizon-
tal manner only - see Fig. A.
• Do not posion the heater at an angle more than
70° and less than 45° from the mounng surface as
shown in Fig. A.
• Always allow the heater to cool before aempng
to reposion/move. Never aempt to move the
heater while it is switched on!
• Observe the minimum safe distance between the
heater body and inammable surfaces and objects
when mounng.
• Do not install the heater in a corner.
1. Securely fasten the Eclipse brackets to the mounng
surface using the xing holes in the brackets. See
Fig.s B, C and D for mounng hole centres of the
Model Triple Quad
kW 230V N & E 1Ph 50Hz
Power kW 1.5 2.25 3.0
Current A 6.5 9.8 13.0
IPX4
Weight kg 5.2 7.1 8.9
Use MCB type 3 or C
CAUTION!
CAUTION!
CAUTION!
NOTE:
NOTE:
NOTE:
CAUTION
Always isolate the heater from the mains supply when
mounng or adjusng the heater posion.
Fig. A
Triple
Quad
45
O
Max
Minimum clearance to
2m
Floor Level
Fig. A