User's Guide

EXIT
N.C.
N.O.
COM
CTL
12V
GND
PB
12V
GND
12V
GND
N.O.
12V
GND
12V
GND
DDR
CN4
CN8
CN2
AR-721RB
12V
327-E
727-E
1
2
3
4
5
6
7
8
1 2 3
4
7
6
5
4
3
2
1
CN18
727-E
727-E
LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
N.C.
N.O.
COM
CTL
12V
E
BZ
RLED
GLED
WG 1
12V
GND
1
2
3
6
12V
GND
Exit Switch
12V
GND
CN5
CN4
BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB
7
8
N.C.
EXIT
1
2
3
4
5
6
7
8
5
4
WG 0
7
6
5
4
3
2
1
CN18
727-E
727-E
LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
WG Port
WG Port
WG Port
WG Port
Main Port
Main Port
RTE
Controller
Controller
Reader
RTE
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Door Contact
Strengthen security with AR-721RB
Electric Bolt
Electric Bolt
Connect to Reader
Access programming mode
Add/Delete
Add -> RF-Learn
Input 5/6-digit user address
Input Tag Units(pcs)
Close Tag into RF Area
If adding a batch of Sequential tags, please input Tag Units(pcs) in the quantity of the tags and present the
tag with the lowest card code to the access controller.
1 2
Adding Tag by RF Learn Function
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Adding and Deleting Tag
User capacity: 16384 (00000~16383)
Access programming mode
Add/Delete
Add -> Card ID
Input 5/6-digit user address
Input Site Code
Input Card Code
1
1
Adding Tag by Tag ID
Access programming mode
Add/Delete
Delete -> Addr
Input Starting address
Input Ending address
1 5
Deleting User Address
Access programming mode
User Setting
Access Mode
Input User Address
0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2 2
Setting up the access mode
Access programming mode
Add/Delete
Delete -> ID #
Input Site Code
Input Card Code
1 6
Deleting Tag by Tag ID
D. PIN Code
C. Initial setup
Access programming mode
User Setting
Password
Input
5/6-digit user address
Input 4-digit PIN (0001~9999)
Succeeded Or via
701Client set it on Users screen
2
1
Node ID of Reader Setting
Access programming mode
Parameters[1]
Node
ID
Input New Node ID : 1~254 (default value:001)
Main
Door Number : 0~255
WG1 Door Number : 0~255
Show WG Message (0=No,1=Enable)
Network setting
Succeeded
3 1
Language Setting
Access programming mode
Tools
Language
0
EN
Succeeded
Initial system...
5 1
F. Enable Voice Module (supporting version : F/w Ver 3.02
or later)
Software Setting
701 Server
or
Programming
B. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode
Tools
Master Code
Input the 6-digit new master code
Succeeded
5 2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard.
Press again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master
Code= 876112, input
876112
Access programming mode
P.S.If entering no instruction within 30 sec., it will automatically
leave the programming mode.
Exiting
Press the repeatedly
Quit or Quit and Arming
(Please refer to alarm / arming setting)
6 7
E. Setting up the alarm / arming
Conditions: 1. Arming enabled 2.Alarm system connected
Application:
1. Door open too long: Door is open longer than door relay time plus door close
time.
2. Force open (Opened without a valid user card): Access by force or illegal
procedure.
3. Door position abnormal: When power is o󰀨 and then on, reader on arming
before power o󰀨.
Step 1. Click "Read."
Step 2. Select "Card
Reader" in RS485-2
section.
Step 3. Click "Write" to
nish the setting.
Hardware setting
Access programming mode
Tools
Ext. Comm Port
Voice
5
5
2
The Wiring of Disable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL
The Wiring of Enable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL)