User's Guide

SOYAL
ACCESS CONTROL SYSTEM
®
AR-327-E / 727-E
V210823
AR-327-E AR-727- E
18/02 FRI Duty:0
18/02 FRI Duty:0
10:49:34
10:49:34
Ready......
Ready......
P
W
R
E
R
R
02
24
14 : 49 : 04
FRI
Duty
:
0
1
2
3
4
5
6
7
8
E
12V
GND
Exit Switch
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
CN4
EXIT
7
6
5
4
3
2
1
CN18
727-E
727-E LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
EXIT
N.C.
COM
PB
12V
GND
N.O.
N.O.
COM
N.C.
V+
V-
7
6
5
4
3
2
1
CN18
727-E
727-E LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
CN4
1
2
3
4
5
6
7
8
12V
GND
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
CN4
EXIT
7
6
5
4
3
2
1
CN18
727-E
727-E LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
Door Contact
ALM
12V
GND
12V
GND
12V
GND
12V
GND
N.C.
CN4
N.C.
N.O.
COM
CTL
12V
1
2
3
4
5
6
7
8
7
6
5
4
3
2
1
CN18
727-E
727-E LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
E
12V
GND
12V
GND
12V
GND
12V
GND
PB
PB
COM
COM
N.O.
N.O.
CN4
CN4
12V
GND
12V
GND
PB
COM
N.C.
CN4
EXIT EXIT
7
6
5
4
3
2
1
CN18
727-E
727-E
LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
7
6
5
4
3
2
1
CN18
727-E
727-E
LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
7
6
5
4
3
2
1
CN18
727-E
727-E
LCD-PCB
7
6
5
4
3
2
1
327-E
CN18
EXIT
WG Port WG Port WG Port
WG Port
WG Port
WG Port WG Port WG Port
WG Port
WG Port
WG Port
WG Port
WG Port
WG Port
Main Port
Main Port
Main Port Main Port Main Port
Main Port
Main Port
Optional Cables
Connect to Electric Bolt
Wiring Diagram
Controller
RTE
POWER
12VDC
POWER
12VDC
Controller
RTE
POWER
12VDC
POWER
12VDC
Magnet Lock
Connect to Magnet Lock
Connect to Electric Strike Connect to Door Contact
Controller
RTE
POWER
12VDC
POWER
12VDC
Electric Strike
If any re emergency, the people can escape by press a switch to open all doors
RTERTE
RTE
POWER
12VDC
POWER
12VDC
Electric Strike
Electric Bolt
Fire Emergency
Transistor
IN4007
Transistor
IN4007
Transistor
IN4007
Magnet Lock
Controller
POWER
12VDC
POWER
12VDC
Alarm
Relay Outpot Module
Door
Contact
Front Panel & Indicator
Data
Week
Work Status
Data [e.g.] 02/24←→02 24(Network Connected)
Week
Work Shift Status
Esc/Quit
Up
Down
Left
Right
Enter/OK
Power(Green)
Alarm(Red)
Arming (Green)
Esc/Quit
Up
Down
Left
Right
Enter/OK
OK(Green)
Error (Red)
In processing (Green)
Power(Green)
Alarm(Red)
Arming (Green)
Wire Application Wire Color Description
TTL Port for
Lift Control or Voice
Module
(*Required speaker
8Ω / 1.5W (Max.
2W)
1 Black DC 0V
2 Yellow
TX
3 White
TE
4 Orange
RX
5 Red DC 5V
6 --- ---
Wire Application Wire Color Description
HID ProxII RF
Module
1 Orange
ANT 1
2
Purple
ANT 2
3 Black DC 0V
4 Red DC 5V
5 Blue Wiegand DAT: 1 Input
6 Green Wiegand DAT: 0 Input
7 White --
Cable: AR-327-E: CN10 / AR-727-E: CN18
P8Cable: CN11
(Optional:Lift Control w/ AR-725L485; SW:RS485-2)
P7
CN9
(Optional:Voice Module; SW:RS485-3)
P9
OK(Green)
Error (Red)
In processing (Green)
POWER
12VDC
Electric Bolt
The Wiring of Enable "Share Door Relay" ( Set up via the parameters setting Window of 701ServerSQL