TECHNICAL DATA:
STANDARD FINISH: US32D
LOCK BODY: Stainless steel
FACE PLATE: Stainless steel
LATCHBOLT: Stainless steel
DEADLOCK ACTUATOR:
Stainless steel
ELECTRICAL: 24 VDC,
1.5 watt continuous duty
Swing Chart: Specify circled swing number when ordering.
AIR REQUIREMENT:
Consumption: .44 cubic
inches per operation
Supply pressure:
80 - 100 P.S.I. at the door
LOCK SIZE:
10 -5/8"H x 1-1/2"W x 1- 3/4"D
LOCK WEIGHT: 3.2 lbs.
LATCHBOLT SIZE:
1- 5/8"H x 5/8"TK
LATCHBOLT THROW: 3/4"
BUILDER’S CYLINDER:
1- 5/32" diameter with
standard Yale cam or equal
UL Listed for use on three-
hour fire doors
UL Listed as burglary
resistant
ASTM F 1577 Certified
Impact Test-Grade 1
P N E U M A T I C L O C K S
JAMB MOUNTED FOR
SWINGING DOORS
Minimum and medium security.
Frame Preparation
NOTE: Drawing for illustration only. Reference template
for specific Information.
1-11/16" O.D. x 1/8"
wall cold drawn tubes
are required.
S
ee Note 1
C6 Printed in USA SS Rev. 04-14
P.O. Box 2021, San Antonio, TX 78297
Ph: 210. 533.1231
Fx: 210. 533.2211
Web: www.SouthernFolger.com
Email: info@southernfolger.com
STANDARD FEATURES:
Deadlock indication switch
Mechanical latchback
Strike with security fasteners
Faceplate with security fasteners
Plug connector
Solenoid valve
Fail secure
Mounting fasteners
Note #1: 1-11/16" O.D. x 1/8" wall cold drawn
tubes furnished by hollow metal manufacturer.
OPTIONAL FEATURES:
NO LATCHBACK - Latchbolt remains retracted
as long as control switch is activated. Latchbolt
extends when power is removed. Specify “NL.”
LOCAL ELECTRIC KEYSWITCH - Day key
provides local electric operation and may be
disabled from remote control point. Master key
provides both electric and mechanical
operation. Specify “LEK.”
EMERGENCY EXIT RELEASE - From remote
location latchbolt can be retracted and held
retracted until released from remote station.
Requires a second pneumatic tube to the lock
and an emergency reserve air system. Specify
“EER.” UL listing for fire door (GYQS) not
available with this function.
BUILDER’S HARDWARE CYLINDERS -
Specify:
“10300P-1” keyed one side.
“10300P-2” keyed both sides.
KEY CYLINDER EXTENDER -
Required whenever lock is keyed on stop side.
Overall frame depth 4" minimum. Specify “KCE.”
Full body rim cylinder required on stop side.
Full body mortise cylinder required on hinge side.
PROVIDE: (See Fig. 1)
1. Dimension “A” (overall frame width)
2. Dimension “B” (edge of frame to centerline
of lockbolt)
10300P PNEUMATICALLY