Product Sheet

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
REAR VIEWFRONT VIEW
24" (610)
37-1/2"
(953)
24"
(610)
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
36"
(914)
TOP VIEW
20"
(508)
Optional
Rear Gas
Connection
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
33-3/4"
(857)
5" (128)
SIDE VIEW of MODULAR MODEL
Front Gas
Manifold
9-1/4"
(235)
20-1/2"
(521)
8-1/2" (216)
10
"
(254)
4" Step-Up
Burner Option
Optional Shelf
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
*(+/- 1” tolerance)
6” (152)
9-3/4
(248)
P24N-BB P24N-BB-SU P24C-BB P24C-BB-SU
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS: Each unit has a 1-1/4" front manifold that couples to the
adjacent sectional unit(s), and a 1" rear gas connection with a male
NPT connector. Minimum gas supply pressure is 7" W.C. for natural
gas and 11" W.C. for propane. All sectional units require a regulated
gas supply (a pressure regulator must be ordered separately). If
usingaexible-hosegasconnection,theinsidediameterofthehose
must not be smaller than the connector on the unit and must comply
with ANSI Z21.69, providing an adequate means of restraint to
prevent undue strain on the gas connection.
• Ifcastersareusedwithaexible-hosegasconnection,a
restraining device should be used to prevent undue strain
on the hose.
Minimum clearance from noncombustible construction is
zero. Minimum clearance from combustible construction is
10" (254 mm) on sides and 6" (152 mm) on rear.
Installation under a vented hood is recommended.
• Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement.Wereservetherighttochangespecicationsand
product design without notice. Such revisions do not entitle the buyer
to corresponding changes, improvements, additions or replacements
for previously purchased equipment.
External pressure regulator
Front rail options:
Cutouts in front rail for sauce pans
7-1/4" deep front rail (to match old
style sectional)
Square belly bar mounted on
7-1/4" deep front rail
Casters (front two casters lock)
Cable restraint kit (to restrict
movement when on casters)
24"or36"highueriser
Shelvesonueriser(oneon24"ue
riser,oneortwoon36"ueriser,10"
deep)
Tray or tubular shelves (12" deep)
Open-frame base with casters for
battery
Extra-deeprear-extendingueriser
Removable shelf inside cabinet
Removable, cast iron grate tops
Battery spark ignition
Form P24-BB Rev 9 (April/2014)
Dimensions shown in inches and (millimeters)
Shipping Crate DimenSionS & Weight
moDel WiDth height Depth Volume Weight
P24N-BB
P24N-BB-SU
39"
(991)
21"
(533)
44"
(1118)
20.9 cu ft
(0.59 cu m)
260 lbs
(117.9 kg)
P24C-BB
P24C-BB-SU
39"
(991)
45"
(1143)
44"
(1118)
44.7 cu ft
(1.27 cu m)
400 lbs
(181.4 kg)
moDel
gaS (Btu/hour)
natural propane
P24N-BB
P24N-BB-SU
140,000 140,000
P24C-BB
P24C-BB-SU
140,000 140,000
Solid shelving
has a depth of
10".
Tubed and
Tray shelving
have a depth of