Product Sheet

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
REAR VIEWFRONT VIEW
24" (610)
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
36"
(914)
TOP VIEW
20"
(508)
Optional
Rear Gas
Connection
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
10-1/2"
(267)
33-3/4"
(857)
5" (128)
SIDE VIEW of MODULAR MODEL
Front Gas
Manifold
20-1/2"
(521)
8-1/2" (216)
11-3/4"
(298)
Optional Shelf
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
6" (152)
(+/- 1” tolerance)
37-1/2"
(953)
22-5/8"
(575)
11-1/4"
(286)
17-3/4"
(298)
P24N-PP P24C-PP
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS:Eachunithasa1-1/4"frontmanifoldthatcouplestothe
adjacentsectionalunit(s),anda1"reargasconnectionwithamale
NPTconnector.Minimumgassupplypressureis7"W.C.fornatural
gasand11"W.C.forpropane.Allsectionalunitsrequirearegulated
gassupply(apressureregulatormustbeorderedseparately).If
usingaexible-hosegasconnection,theinsidediameterofthehose
mustnotbesmallerthantheconnectorontheunitandmustcomply
withANSIZ21.69,providinganadequatemeansofrestraintto
preventunduestrainonthegasconnection.
• Ifcastersareusedwithaexible-hosegasconnection,a
restrainingdeviceshouldbeusedtopreventunduestrain
on the hose.
• Minimumclearancefromnoncombustibleconstructionis
zero.Minimumclearancefromcombustibleconstructionis
10"(254mm)onsidesand12"(305mm)onrear.
• Installationunderaventedhoodisrecommended.
• Checklocalcodesforreandsanitaryregulations.
NOTICE:Southbendhasapolicyofcontinuousproductresearch
andimprovement.Wereservetherighttochangespecicationsand
productdesignwithoutnotice.Suchrevisionsdonotentitlethebuyer
tocorrespondingchanges,improvements,additionsorreplacements
forpreviouslypurchasedequipment.
Externalpressureregulator
Frontrailoptions:
Cutoutsinfrontrailforsaucepans
7-1/4"deepfrontrail(tomatchold
stylesectional)
Squarebellybarmountedon
7-1/4"deepfrontrail
Casters (front two casters lock)
Cable restraint kit (to restrict
movement when on casters)
24"or36"highueriser
Shelvesonueriser(oneon24"ue
riser,oneortwoon36"ueriser,10"
deep)
Trayortubularshelves(12"deep)
Open-framebasewithcastersfor
battery
Extra-deeprear-extendingueriser
Removableshelfinsidecabinet
FormP24-PPRevRev2(January/2016)
Dimensions shown in inches and (millimeters)
Shipping Crate DimenSionS & Weight
moDel WiDth height Depth Volume Weight
P24N-PP
39"
(991)
21"
(533)
44"
(1118)
20.9 cu ft
(0.59 cu m)
250 lbs
(113.4 kg)
P24C-PP
39"
(991)
45"
(1143)
44"
(1118)
44.7 cu ft
(1.27 cu m)
330 lbs
(149.7 kg)
Model
Gas (BTU/hour)
Natural Propane
P24N-PP 32,000 31,000
P24C-PP 32,000 31,000
Solid shelving has
a depth of 10".
Tubed and Tray
shelving have a
depth of 11-1/8".