Product Sheet
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
REAR VIEWFRONT VIEW
24" (610)
37-1/2"
(953)
24"
(610)
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
36"
(914)
TOP VIEW
20"
(508)
Optional
Rear Gas
Connection
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
33-3/4"
(857)
5" (128)
SIDE VIEW of MODULAR MODEL
Front Gas
Manifold
9-1/4"
(235)
20-1/2"
(521)
8-1/2" (216)
11-3/4"
(298)
Optional Shelf
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
*(+/- 1” tolerance)
6” (152)
9-3/4
(248)
P24N-HH P24C-HH
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS: Each unit has a 1-1/4" front manifold that couples to the adja-
cent sectional unit(s), and a 1" rear gas connection with a male NPT
connector. Minimum gas supply pressure is 7" W.C. for natural gas
and 11" W.C. for propane. All sectional units require a regulated gas
supply (a pressure regulator must be ordered separately). If using a
exible-hosegasconnection,theinsidediameterofthehosemust
not be smaller than the connector on the unit and must comply with
ANSI Z21.69, providing an adequate means of restraint to prevent
undue strain on the gas connection.
• Ifcastersareusedwithaexible-hosegasconnection,a
restraining device should be used to prevent undue strain
on the hose.
• Minimum clearance from noncombustible construction is
zero. Minimum clearance from combustible construction is
10" (254 mm) on sides and 12" (305 mm) on rear.
• Installation under a vented hood is recommended.
• Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement.Wereservetherighttochangespecicationsand
product design without notice. Such revisions do not entitle the buyer
to corresponding changes, improvements, additions or replacements
for previously purchased equipment.
External pressure regulator
Front rail options:
Cutouts in front rail for sauce pans
7-1/4" deep front rail (to match old
style sectional)
Square belly bar mounted on 7-1/4"
deep front rail
Casters (front two casters lock)
Cable restraint kit (to restrict
movement when on casters)
24"or36"highueriser
Shelvesonueriser(oneon24"ue
riser,oneortwoon36"ueriser,10"
deep)
Tray or tubular shelves (12" deep)
Open-frame base with casters for
battery
Extra-deeprear-extendingueriser
Removable shelf inside cabinet
Form P24-HH Rev 7 (April/2014)
Dimensions shown in inches and (millimeters)
Shipping Crate DimenSionS & Weight
moDel WiDth height Depth Volume Weight
P24N-HH
39"
(991)
21"
(533)
44"
(1118)
20.7 cu ft
(0.59 cu m)
231 lbs
(104.8 kg)
P24C-HH
39"
(991)
45"
(1143)
44"
(1118)
44.7 cu ft
(1.27 cu m)
349 lbs
(158.3 kg)
moDel
gaS (Btu/hour)
natural propane
P24N-HH 64,000 56,000
P24C-HH 64,000 56,000
Solid shelving has
a depth of 10".
Tubed and Tray
shelving have a
depth of 11-1/8".