Product Sheet

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
37-1/2"
(953)
24"
(610)
REAR VIEW
6" (152)
20"
(508)
FRONT VIEW
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
12"
(305)
36"
(914)
TOP VIEW
9-1/4"
(235)
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
33-3/4"
(857)
5" (127)
8-1/2" (216)
SIDE VIEW of MODULAR MODEL
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
Front Gas
Manifold
Rear Gas
Connection
*(+/- 1” tolerance)
8-3/4"
(222)
P12N-C P12C-C
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS: Each unit has a 1-1/4" front manifold that couples to the
adjacent sectional unit(s), and a 1" rear gas connection with a male
NPT connector. Minimum gas supply pressure is 7" W.C. for natural
gas and 11" W.C. for propane. All sectional units require a regulated
gas supply (a pressure regulator must be ordered separately). If
using a exible-hose gas connection, the inside diameter of the hose
must not be smaller than the connector on the unit and must comply
with ANSI Z21.69, providing an adequate means of restraint to
prevent undue strain on the gas connection.
If casters are used with a exible-hose gas connection, a
restraining device should be used to prevent undue strain
on the hose.
Minimum clearance from noncombustible construction is
zero. For use in noncombustible locations only.
Installation under a vented hood is recommended.
Check local codes for re and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement. We reserve the right to change specications and
product design without notice. Such revisions do not entitle the buyer
to corresponding changes, improvements, additions or replacements
for previously purchased equipment.
Front rail options:
Cutouts in front rail for sauce pans
7-1/4" deep front rail (to match old
style sectional)
Square belly bar mounted on 7-1/4"
deep front rail
Casters (front two casters lock)
Cable restraint kit (to restrict
movement when on casters)
24" or 36" high ue riser
Open-frame base with casters for
battery
Extra-deep rear-extending ue riser
Removable shelf inside cabinet
Plated sh grids
External pressure regulator
Form P12-C Rev 8 (April/2014)
Dimensions shown in inches and (millimeters)
Model
Gas (BTU/hoUr)
NaTUral ProPaNe
P12N-C 32,000 28,000
P12C-C 32,000 28,000z
shiPPiNG CraTe diMeNsioNs & WeiGhT
Model WidTh heiGhT dePTh VolUMe WeiGhT
P12N-C
20"
(508)
21"
(533)
42.5"
(1080)
10.3 cu ft
(0.29 cu m)
175 lbs
(79.4 kg)
P12C-C
20"
(508)
45"
(1143)
42.5"
(1080)
22.1 cu ft
(0.63 cu m)
225 lbs
(102.1 kg)