Datasheet

3
UTL series
Technical features
Mechanical
• Durability:1000cycles
(with stamped & formed contacts &
S18 plating)
• Vibrationresistance:Sinusoidal
vibrations per IEC 60512-4 -
from 10 to 2000 Hz
• Bodyconnector+Backshell:
Thermoplastic
• Insert:Thermoplastic
• Nut:Metal
Electrical
• Workingvoltage:
277VACperUL1977
277/480VACperUL1977
• Ratedcurrent:16A
• Connectorforbreakingcircuit
Environmental
• Operatingtemperature:
from-40°Cto+105°C
• Flammabilityrating:UL945VA
• Saltspray:1000 hours
• UVresistant:F1materialperthe
UL 746C
• Sealing:
- IP68/69K - IP6X mated &
unmated
-IPX8:mated(10m.underwater
during 1 week)
-IPX8:unmatedwithsealedcontact
(1m. underwater during 1 week)
Cable assembly
Souriau provides connectors in various applications for more than 90 years in the most extreme environment. Being conscious
about the difficulty to find a quick and a reliable harness manufacturer, we decided years ago to start in house cable
assembly production. It allows customers to reduce the number of suppliers, and to take advantage of the "best in class" quality of the
Souriau group. Overmoulding is a process that further enhances the sealing properties of the UTL range, especially over many years of
use. Overmoulding provides the opportunity to change the cable exit from straight through 90 degrees and avoid any stress on the cable
terminated to the connector. Also, as the wires are encapsulated inside the moulding, a barrier is created which prevents from any liquid from
entering the equipment through the connector if the cable jacket is breached.
Compound
O ring
PVC or PUR
overmolding