Datasheet

22
CLIPPER
The CLIPPER connector must be equipped with an
adaptor in order to use a PG electrical thread backshell
(e.g.: cable clamp or sealing gland, or flexible conduits
system backshells, etc.)
1) Manually, fully screw the adaptor on
the connector, the hexagonal nut
towards the rear.
2) In the sealed version, cover the
O-ring.
3) Manually, fully screw the PG thread
backshell of your choice.
Note: In the case of an elbow backshell, it is
possible to adjust the position according to
the angle desired.
1) Position the O-ring at the bottom of the backnut.
2) Run the backnut around the cable.
3) Unlock the retainer plate.
4) Position the grommet in the thrust ring, resting
against the retainer plate.
5) Insert the contacts through the grommet and the
retainer plate.
6) Lock the retainer plate.
7) Screw the backshell.
Instruction for polarizing connector mounting
When the insert is partially filled with contacts, place
polarization contact into selected hole location in the
FEMALE INSERT and push in until seated.
• Polarization contacts are used to provide keying
capabilities for the CLIPPER series.
• Polarization contacts are used in the socket-cavities
of standard plugs and reverse receptacles.
In order to lock the couple of chosen connectors, you
have to let free the cavity in front of the polarization
contact.
To avoid the connection with other connectors, you
have to insert a contact in the cavity in front of the
polarization contact.
Instruction For Assembly
Adaptor and PG electrical thread backshells
Grommet
Thrust ring
O ring
Heat shrink boot
Shrink sleeve as follows :
1) Use heat gun with an air deflector nozzle.
2) Adjust air deflector opening to accommodate tubing
size. Turn switch ON. Wait until full heat output is
reached.
3) Position the air deflector over section of tubing to be
shrunk. Start at pre-shrunk section and work
towards open end.
4) When tubing begins to shrink, move gun so that air
is distributed in a band around the tubing
circumference causing it to shrink evenly around the
cable.
5) Move nozzle to adjacent section and shrink in the
same manner. Repeat process on section at a time
until entire length is shrunk.
Avoid excessive heat. Direct heat away from connector
assembly to prevent damage.
Grommet Backshell Assembly
CP16SW9700