CLIPPER
TOOLING
Machined Crimping Contacts (#16 and #20)
Y16SCMCL3
8365
with
locator
8365-02
• Squeeze the plier handles until a final click sounds, release, the pliers
should open by themselves.
• Fully insert the contact into the locator (corresponding gauge), the
contact crimping lugs should be directed upwards, according to the
drawing.
• Put the stripped wire in the crimping part until it comes in contact with the
stopper plate. Make sure that no strands stick out of the crimping part.
• Squeeze the plier handles until a final click sounds, release, the pliers
should open by themselves.
• Check the overall aspect of the crimping.
• Push the cable into the contact barrel and make sure the cable strands
stick out of the inspection hole.
• The pliers must be used on the jaws side.
• Squeeze the plier handles until a final click sounds, release, the pliers
should open by themselves.
• Insert both wire and contact (or wire, reducing sleeve and contact)
between the 4 jaws until stopped by the locator.
• Fully squeeze until a final click sounds, the pliers should open once the
crimping is performed
• Extract the wire and crimped contact, then check the overall aspect of
the crimping.
Manual Crimping Tool