Fire Pit Manual

HOSE & REGULATOR ASSEMBLY AND REPLACEMENT
1. This replace comes equipped with a standard LP gas hose and regulator including the
appliance side connection for a CGA No 791 Cylinder Connection Device. The LP gas hose
and regulator supplied with this re table must be used. Only a hose and regulator specied
by manufacturer can be used for replacement.
a. The CGA No 791 connection incorporates a magnetic ow limiting device that acts to
limit the ow of gas if a leak is detected between the regulator and the burner va
lve.
b. If the burner valve is open prior to the LP gas cylinder service valve being opened, the
connection will interpret this free ow of gas to be a leak.
c. The connection safety feature will reduce gas ow from the regulator to the appliance to
a minimal level.
d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder
service valve to ensure that the connection ow limiting device is not triggered mistakenly.
e. If the connection
ow limiting device is triggered mistakenly, close the LP gas cylinder
service valve and the burner valve, wait 10 seconds to allow the device to reset, open the
cylinder service valve, then open the burner valve and light the replace as per lighting
instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose
contacts any hot surface
3. Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the
re table. If the hose shows signs of cracks,
abrasions, cuts or damage of any kind, do not operate the appliance. Fix or replace the
hose as required before using the appliance. For assistance with repair or replacement of
the hose,
b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when
replacing the cylinder or at least once per year. If there is any indication of damage, have
the seal replaced by a certied gas dealer before operating the appliance.
4
. Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service
valve. Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the CGA No 791
connection on to the LP gas cylinder service valve.
6. “Leak Test” should always be performed after attaching the connection to the LP gas cylinder
service valve. (See “Checking for Leaks” section of this manual on page 10)
7. For the connection of the hose and regulator to the LP tank,
refer to the “Connection” section of
the LP gas cylinder section above.
7/20
call the supplier. Use only replacement parts from the manufacturer.