Front View
Rear View
DETAILS
The Compact Stagebox requires the addition of a standard D21m MADI card to the Vi or Si option card
slot. It contains 3 slots for audio I/O modules, 2 slots for optional D21m I/O modules and the D21m
MADI HD card providing the Compact Stagebox-to-console connection. Slots are labeled from top to bot-
tom A/C/E for I/O modules and K/L for the optional D21m card slots. These labeling references are used
by the patching system when the user wishes to patch the connectors to input channels or output busses.
Primary Power Supply
The primary power supply connectors are located on the rear panel. Both primary power supplies connect
to the IEC inlets via their power switches and provide a full range AC inlet, converting 100 to 240 V AC to
24 V DC. The Compact Stagebox is normally tted with two power supplies, providing redundancy for those
requiring it.
Module Function Overview
Normally two mic/line input and one line/AES output modules are tted, giving 32 inputs and 16 outputs.
However, more input or output modules, up to a maximum of 3 modules giving 48 inputs or outputs, can
be tted.