Use and Care Manual

INSTALLATION METHODS
FLOATING FLOORS
1. Roll out underlayment vapor barrier side up and butt seams together
2. Tape seams with provided lip & self seal tape
3. Click & lock floating floors over the top according to manufacturer
DOUBLE GLUED DOWN FLOORS
1. Roll out underlayment with the vapor barrier side up and butt
seams together
2. With a utility knife cut off the overhanging lip/flap before
applying adhesive
3. Adhere to subfloor using recommended flooring manufacturer’s
adhesive and recommended trowel size and install method
4. Roll over the underlayment with a 75 or 100 pound roller
5. Adhere flooring over the top using manufacturer’s recommended
adhesive and trowel size
*ENSURE TO READ THE COMPLETE INSTALLATION INSTRUCTIONS BEFORE INSTALLATION
ADVANTAGES
Excellent sound rating: Delta
sound rating = 23
Exceeds requirements for moisture vapor transmission
Superior compression characteristics for support
Reduces reflective noise & floor sound transmission
Can use over concrete and wood subfloors
Suitable over radiant heated floors
Features lip & tape for easy and fast installation
Eliminates minor subfloor imperfections
Humidity, mold & mildew resistant
LIMITATIONS
SoundStep is not suitable for use as underlayment for:
Ceramic tile • Carpet
Sheet-vinyl • VCT
Installations over concrete in high moisture areas (vapor emission
rate above 3 lbs/ 1000 sq ft/ 24 hrs) will require additional protection
such as a concrete sealant or polyethylene vapor barrier.
APPROVED SUBSTRATES
Dry, completely cured concrete (at least 28 days old)
Concrete and masonry blocks
Cement backer units (CBU)
Cementitious screeds, leveling coats and mortar beds
Waterproofing and crack-isolation membranes
Wood, plywood, or OSB subfloors that meet NWFA Subfloor Guidelines
and Specifications, and meet applicable building codes.
Cement terrazzo floors
PACKAGING
48” x 25’ (100 sq ft) do-it-yourself size rolls.
Rolls per pallet: 50
Pallets per truck: 64
Rolls per Truck: 3200
TECHNICAL DATA
Weight ........................................................................ 5 lbs per roll
Thickness ................................................................................2mm
Density ....................................................................... 5# (+/-10%)
WVTR ................................................... 0.16lbs/1000ft
2
/24 hour day
• Compression Resistance @ 25% (ASTM D1667) ............... 13.6psi
• Compression Resistance @ 30% (ASTM D1667) ............... 17.8psi
• Compression Resistance @ 50% (ASTM D1667) ............... 47.2psi
• Compression Set @ 25%
(ASTM D1668) ............................ 12.6%
• Breaking Strength ........................................................ 22.1 lbs
SOUND PROPERTIES
IMPACT SOUND TRANSMISSION
The method is designed to measure the impact sound transmission
performance of a floor-ceiling assembly in a controlled laboratory
environment.
IIC Flooring Sub-oor
67 Laminate over a 6” concrete suboor with a suspended ceiling
74 8mm WPC with ceiling assembly
SOUND TRANSMISSION LOSS
The sound-insulating property of a partition element is expressed in
terms of the sound transmission loss.
STC Flooring Sub-oor
63 Laminate over a 6” concrete suboor with a suspended ceiling
61 8mm WPC with ceiling assembly
DELTA TEST
Tests the impact insulation difference between a bare concrete subfloor
with no flooring materials and the same concrete subfloor with flooring
and underlayment.
Delta IIC Flooring
Up to 23 SoundStep XL under Wood Plastic Composite (WPC)
SSXLPE100BLSS