Manual

USBPre 2 User Guide and Technical Information
16
Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.
same sample rate as that of the incoming digital signal (See Installation and Connection section for your
operating system).
If the USBPre 2 senses a discrepency in the incoming digital signal such as a clocking error, the Meter
Source LED will flash until the Meter Source button is pushed.
Setup Examples
Test and Measurement
The high quality preamplifiers and portability of the USBPre 2 make it a perfect interface for test and
measurement applications. A requirement for measuring a transfer function is the ability to moni-
tor the output reference signal from the computer. The LOOP source of input 2 enables a copy of the
computer audio left channel to be internally routed to input 2. This allows reference signal to be sent
back into the measurement application without additional cabling.
The USBPre 2 supports native sample rates below 44.1 kHz to provide better FFT resolution for low-
frequency audio measurements.
Input 1 set to Mic (XLR)
Input 2 set to Loop
To PA