15
Meters
Selected Preset
METER PRESETS 1-12
A. PEAK HOLD TIME Selects the peak hold time for the meter
preset. [Off, 1*-5s., Innity]
B. METER RANGE Selects the range of the meters from bottom to
top of scale. [50 dB*, 40 dB, 20 dB]
C. METER VIEW Selects the meters to be viewed in the current
preset. [LR,1-8, LR,9-16, LR,17-24, LR,25-32, LR,1-16, LR,17-32,
LR,1-12, LR,13-24, LR,1-32, LR,Outputs, LR,Buses, LR,Returns]
D. TRACK NAMES Selects display of track name in meters.
[Enabled*, Disabled]
E. GRAY METERS Selects gray meter when record disarmed. [When
disarmed*,Off]
Timecode
TIMECODE MODE Selects the timecode mode of operation. [Off,
Record Run, Free Run*, Free Run Auto Mute, Free Run Jam Once, 24
Hour Run (ToD), 24 Hour Run Auto Mute, Ext TC, Ext TC - Auto Record,
Ext TC Continuous, Ext TC Cont. - Auto Record]
FRAME RATE Selects the current frame rate. [23.98, 24, 25, 29.97
ND, 29.97 DF, 30 ND*, 30 DF]
HOLD OFF Selects the amount of time incoming Timecode needs
to be valid prior to entering record. [0.0*-8.0 seconds in steps of 0.1
sec.]
JAM Indicates the Received TC, Generator TC and the calculated
difference between the two. Received and Generator UBits are shown.
Jamming to external TC and UBits is supported.
a. Jam TC- Toggle Rtn/Fav switch to jam to external TC.
SET GENERATOR TC Provides the ability to start rolling internal TC
from a manually entered value in the format of HH:MM:SS:ff
SET GENERATOR UBITS Provides UBits manual and automatic
entry. [U=User entered UU:UU:UU:UU*, mm:dd:yy:UU, dd:mm:yy:UU,
Use External] Use Rtn/Fav toggle to exit.
LEMO OPTIONS Selects Pin 2 and Pin 5 options for TC Lemo
connector.
a. Pin 2 - [TC In*, WCK In, WCK Out]
b. Pin 5 - [TC Out, WCK Out]
SYNC REFERENCE Selects current sync reference. [Internal*, Word
Clock, LTC In]