Product Manual
TROUBLESHOOTING GUIDE
PROBLEM
will not rotate
Low pump capacity
POSSIBLE CAUSE
• Outlet plugged
• Stripped or damaged gears
• Motor faulty
• Debris ingested
SOLUTION
• Check for blockage and clear.
• Check power source.
• Repair or replace motor.
Replace complete assembly if necessary.
• Replace motor.
• Check power source.
• Repair leaks.
• Dismantle and clean.
• Add inlet screen.
Fluid Leakage
• Motor faulty
• Faulty or missing gaskets
• Loose bolts
• Cracked component
• Shorten duty cycle.
• Replace motor.
Regulatory Compliance Informaon
Model / Accessories
/ Conguraon Informaon