Safety data sheet

Soshine International
Library Sort
Product Specifications
VER
A01
Library Name
Li-ion Rechargeable Battery
Date
2018/08/28
2 Characteristics
2.1 Standard Charge This "Standard Charge" means charging the cell with charge current 1800mA and constant
voltage 4.2V at 25 for 3hours.
2.2 Standard Discharge Capacity The standard discharge capacity is the initial discharge capacity of the cell,
which is measured with discharge current of 720mA with 2.75V cut-off at 25 within 1hour after the standard
charge. Standard Discharge Capacity 3500mAh
2.3 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge constant current 720mA and 2.75V cut-off
after the standard charge is as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours. Charge Temperature Discharge temperature
25-100 2540
Relative Capacity 50% 80% 100% 80% Percentage as an index of the capacity at 25(=3600mAh) is 100%.
2.4 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge constant current
720mA and 2.75V cut-off after the standard charge is as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage as an index of the capacity at 25(=3600mAh) is 100%.
2.5 Charge Rate Capabilities
Discharge capacity is measured with constant current 720mA and 2.75V cut-off
after the cell is charged with 4.2V as follows.
Note: Percentage as an index of the capacity at 25(=3600mAh) is 100%.
2.6 Discharge Rate Capabilities
Discharge capacity is measured with the various currents in under table and 2.75V
cut-off after the standard charge.
Note: Percentage as an index of the capacity at 25(=3600mAh)