Safety data sheet
Soshine International
Library Sort
Product Specifications
VER
A01
Library Name
Li-ion Rechargeable Battery
Date
2018/08/28
2 Characteristics
2.1 Standard Charge This "Standard Charge" means charging the cell with charge current 1800mA and constant
voltage 4.2V at 25℃ for 3hours.
2.2 Standard Discharge Capacity The standard discharge capacity is the initial discharge capacity of the cell,
which is measured with discharge current of 720mA with 2.75V cut-off at 25℃ within 1hour after the standard
charge. Standard Discharge Capacity ≥ 3500mAh
2.3 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge constant current 720mA and 2.75V cut-off
after the standard charge is as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours. Charge Temperature Discharge temperature
25℃ -10℃ 0℃ 25℃ 40℃
Relative Capacity 50% 80% 100% 80% Percentage as an index of the capacity at 25℃(=3600mAh) is 100%.
2.4 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge constant current
720mA and 2.75V cut-off after the standard charge is as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage as an index of the capacity at 25℃(=3600mAh) is 100%.
2.5 Charge Rate Capabilities
Discharge capacity is measured with constant current 720mA and 2.75V cut-off
after the cell is charged with 4.2V as follows.
Note: Percentage as an index of the capacity at 25℃(=3600mAh) is 100%.
2.6 Discharge Rate Capabilities
Discharge capacity is measured with the various currents in under table and 2.75V
cut-off after the standard charge.
Note: Percentage as an index of the capacity at 25℃(=3600mAh)