User's Manual
Table Of Contents
- 1. Warnings and precautions
- 2. Warranty conditions
- 3. The programmer system
- 4. The programmer tablet
- 5. The programmer software
- 6. The docking station
- 7. The inductive programming head
- 8. The radio frequency (RF) link
- 9. The ECG
- 10. The printer
- 11. Maintenance
- 12. Guidance and manufacturer's declaration
- 12.1. Radio equipment emission
- 12.2. Recommended separation distances according to the maximum output power of the communications equipment
- 12.3. Cable length
- 12.4. Electromagnetic emissions
- 12.5. Magnetic and Electromagnetic Immunity
- 12.6. Electromagnetic Immunity, Portable Radio Frequency Equipment
- 12.7. Raw materials
- 13. Technical data
- 13.1. Conformity of the programmer
- 13.2. US Federal Communications Commissions (FCC) and Industry Canada
- 13.3. Essential performances
- 13.4. Power supply
- 13.5. Dimensions programmer tablet
- 13.6. Dimensions docking station
- 13.7. Dimensions inductive programming head
- 13.8. Use constraints
- 13.9. Storage constraints
- 13.10. System specifications of the programmer
- 14. Explanation of symbols
- 15. Glossary
13. TECHNICAL DATA
NOTE:
For the technical specifications and declaration of conformity of the Radio Frequency (RF)
Link accessory, please refer to the associated user manual.
CONFORMITY OF THE PROGRAMMER
Conformity with Directives 90/385/EEC, 2014/53/EU
Patient safety IEC 60601-1, Class I, BF Type
EMC IEC 60601-1-2
EN 301 489-1
EN 301 489-17
EN 301 489-27
EN 301 489-31
ERM
EN 300 328
EN 302-195
FCC CFR 47
RSS-GEN
US FEDERAL COMMUNICATIONS COMMISSIONS (FCC) AND
INDUSTRY CANADA
Inductive programming head
FCC
CAUTION: changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment
has very low levels of RF energy that is deemed to comply without testing of specific
absorption rate (SAR).
IC: This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This
equipment has very low levels of RF energy that is deemed to comply without testing of
specific absorption rate (SAR).
Cet équipement est conforme aux limites d’exposition aux rayonnements énoncées pour
un environnement non contrôlé et respecte les règles d’exposition aux fréquences
radioélectriques (RF) CNR-102 de l’IC.
Cet équipement émet une énergie RF très faible qui est considérée comme conforme sans
évaluation du débit d’absorption spécifique (DAS).
13.1.
13.2.
13.2.1.
13. TECHNICAL DATA
30 SmartTouch – UA10412A