Manual

2/8
Form 451 (11.13) ©SOR Inc.
Installation
MD Remote Option (includes plundger, 20 foot cable and two crimps.)

Screw plunger to the top of unit.
Thread the 20’ cable through the hole in plunger and create a 14 inch top loop as
shown below.

At the bottom of the cable, a second loop can be created as a handle for actuation at
the desired length.
The unit may be mounted in any of the following installation arrangements:

1-1/2” NPT half coupling (No full coupling).

2” NPT full coupling. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)

2” NPT pipe tee. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)

Optional flanged mounting.

Optional chamber mounting.
Linear = mm/inches
Drawing 0098636
REMOTE MANUAL CHECK
MD OPTION
CRIMP
REMOTE CABLE
CREATE HANDLE AT DESIRED LENGTH
TOP 14” LOOP
PLUNGER