<Table 1> <Table 2> Remarks
Item Number Data
Item Upper byte Lower byte Data Upper byte Lower byte
USER BIAS RED 00h 53h FFE2h to 001Eh (_30 to 30) Set/Get
USER BIAS GREEN 00h 54h FFE2h to 001Eh (_30 to 30)
USER BIAS BLUE 00h 55h FFE2h to 001Eh (_30 to 30)
Iris Sensitivity 00h 56h Recommend 00h
Fast 01h
Slow 02h
Iris Manual 00h 57h 00h to 64h (0 to 100)
xvColor 00h 5Ah Off 00h
On 01h
Status Error 01h 01h NO ERROR 00h Get only
LAMP ERROR 01h
FAN ERROR 02h
COVER ERROR 04h
TEMP ERROR 08h
D5V ERROR 10h
POWER ERROR 20h
NVM Data ERROR 80h
25h LENS SHUTTER 01h
ERROR
Status Power 01h 02h STANBY 00h
START UP 01h
STARTUP LAMP 02h
POWER ON 03h
COOLING1 04h
COOLING2 05h
SAVING COOLING1 06h
SAVING COOLING2 07h
SAVING STABY 08h
Lamp Timer 01h 13h USE TIME 0000h-FFFFh
*1
Sircs (15bit category) 17h Refer to Table4 ----- 00h 00h Set only
*2
Sircs (20bit category) 19h Refer to Table5 ----- 00h 00h
1Bh Refer to Table6 ----- 00h 00h
*1 Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lower byte.