User’s Guide SX-200/SX-215 User’s Manual Document #40181-420 Rev.
User’s Guide Section 1 – Product Overview........................................................................................................................................7 Introduction.................................................................................................................................................................7 Package Contents..............................................................................................................................................
User’s Guide SH NW ...................................................................................................................................................................43 SET NW AUTHtype ...............................................................................................................................................43 SH NW AUTH ........................................................................................................................................................
User’s Guide SET PORT P1 SOJBUSY ....................................................................................................................................55 CL PORT JOB ........................................................................................................................................55 USB Port Commands................................................................................................................................................56 SET PORT U1 PSTA .....
User’s Guide SET IP PIng .............................................................................................................................................................65 SET IP PRObe ........................................................................................................................................................65 SET IP RARp....................................................................................................................................................
User’s Guide SH SMTP.................................................................................................................................................................76 DLC / NETBEUI Commands.......................................................................................................................................76 SET DLC ENable......................................................................................................................................................
Section 1 – Product Overview Introduction SX-200 Series Print Servers allow you to share a printer equipped with a USB or parallel port on a wired or wireless network. The SX-200 print server supports and automatically senses both 100baseTX Fast Ethernet and 10baseT Ethernet network connections, and the SX-215 wireless version allows connections to 802.11b, and 802.11g wireless networks as well.
User’s Guide About This User’s Guide This User’s Guide contains information on system requirements, basic troubleshooting, and instructions on the following: Installing the print server hardware Configuring the print server for use on your network Windows print queue configuration Macintosh print queue configuration Windows™ System Requirements To configure the print server settings (wired and wireless versions) using the provided ExtendView Utility in Windows, your Windows-based system should inc
User’s Guide Wireless Print Server Requirements To print using the SX-215 wireless print server, you will need an 802.11b or 802.11g wireless network consisting of either of the following: An 802.11b or 802.11g wireless-enabled PC or Macintosh printing straight to the printer (Ad-Hoc or Peer-to-Peer Mode). An 802.11b or 802.11g wireless access point that allows wireless and wired Ethernetenabled computers to print to the wireless print server.
User’s Guide Print Server Components The print server includes the following components. Detailed descriptions of these components are provided below: Power connector – The power supply cable plugs into this connector. Test button – Pressing this button for less than three seconds will print a test page on the printer. Pressing and holding this button for more than five seconds will reset the print server to factory default settings.
User’s Guide LED Indicators The front edge of the print server provides five Green/Orange LEDs (Light Emitting Diode) indicators for easy monitoring. The following table defines the function of each LED. Label Color State POWER GREEN OFF Green ON Green Blinking 10/100 WIRELESS USB GREEN/ORANGE GREEN GREEN/ORANGE (USB PORT MODELS ONLY) PARALLEL GREEN/ORANGE (PARALLEL PORT MODELS ONLY) Document #40181-420 Rev.
User’s Guide Pushbutton Functions The front edge of the print server provides a momentary pushbutton that can be used to print a test/configuration page or reset the device to factory default settings. Action Function Press pushbutton for > 1/8 second but < 5 seconds Prints a test/configuration page on each connected port Press pushbutton for > 5 seconds Resets the device configuration to factory defaults. The unit will reinitialize itself after updating the configuration memory.
User’s Guide Section 2 – Hardware Installation Before You Begin Before installing the print server, make sure you have installed and set up your printer as described in the documentation that came with the printer and that your printer functions properly. SX-200 Series Print Servers support a parallel and/or USB connection to your printer.
User’s Guide 3. Connect the print server to your printer(s) using the USB and/or parallel port of your printer. For a USB connection, use a standard USB A (print server side) to B (printer side) cable. For a parallel connection, use an IEEE 1284-compliant parallel printer cable. 4. Plug the print server power supply adapter into a suitable AC receptacle, and then plug the power supply cable into the print server. The print server will run through a sequence of power-up diagnostics for a few seconds.
User’s Guide Verifying the Connection to the Printer NOTE: Before attempting to print, it is very important to verify the connection between the print server and printer. If this connection is not working, you will not be able to print! 1. Verify that both the print server and the printer are powered on and ready, and that a USB or parallel printer cable is properly connected between the print server and printer. 2. Print a test page by pressing the Test button once.
User’s Guide Section 3 – Configuration and Management Configuration Options SX-200 Series Print Servers (wired and wireless models) can be configured using a variety of options, some of which do not require any software installation on the host PC.
User’s Guide HP Web JetAdmin Utility a web browser-based HP utility (e.g., Internet Explorer or Mozilla). can be downloaded from the HP web site http://www.hp.com. Configuration Console a command-line-oriented console. contains advanced features not available through ExtendView or the Web Browser Interface. the default password is ACCESS. can be accessed via TELNET using the print server’s Ethernet connection. type HELP for a list of console commands.
User’s Guide Configuring the Print Server via an Ethernet Connection For Microsoft Windows operating systems, the ExtendView Utility (provided on the Print Server Installation CD) is the recommended method of configuring one or more print servers on your network.
User’s Guide USING THE WEB BROWSER INTERFACE TO CONFIGURE THE PRINT SERVER (NON-WINDOWS SYSTEMS): To configure the print server using non-Windows operating systems (e.g., Unix systems), a standard web browser (e.g., Microsoft Internet Explorer or Netscape Navigator) can be used to access the print server’s embedded Web (HTTP) server pages, which contain the print server’s configuration options. No additional software is required. 1. Ensure your PC is connected and has access to your network. 2.
User’s Guide USING A THE INTERNAL COMMAND CONSOLE TO CONFIGURE THE PRINT SERVER: The command console can be accessed using a Telnet connection via an Ethernet connection. To use a Telnet connection, follow these steps: 1. 2. Ensure the print server is connected via an Ethernet cable to the host computer. From the Windows Start menu, click on Run, and then type the following command (where x.x.x.x. is the IP address of the print server. telnet X.X.X.
User’s Guide Windows Print Queue Configuration On Windows systems, Silex recommends using the Windows Standard TCP/IP Port for printing. Below is instructions for setting up your printer port on Windows systems. Please note that TCP/IP must be installed on your system, and that screenshots may vary depending on which version of Windows you are using.
User’s Guide Select the local printer, as shown below, and click Next. Document #40181-420 Rev.
User’s Guide Select the 'Create a new port' option (note, your screen may look different depending on which version of Windows you are using) and choose 'Standard TCP/IP Port' from the drop down menu as shown below. Click Next. Document #40181-420 Rev.
User’s Guide The 'Add Standard TCP/IP Printer Port Wizard' will start as shown below. Click Next. Document #40181-420 Rev.
Macintosh Print Queue Configuration Silex Print Servers support the AppleTalk protocol running over Ethernet (also known as EtherTalk). This capability allows Macintosh computers to print jobs to a printer simultaneously with jobs from Windows, UNIX, NetWare, and other computers. NOTE: silex Print Servers are also compatible with the Macintosh TCP/IP Printer option in the Print Center as long as you have a valid IP Address configured (refer to the section “Configuring your print server”).
User’s Guide MACINTOSH CONFIGURATION (OS 10.X) 1. If you have not done so already, set the name of your computer by going to the Applications folder*, selecting System Preferences, and then Sharing. Type in the computer name in the Network Identity section (you can also set the IP address here if you want). 2. Turn on Ethernet and AppleTalk by clicking on the Applications folder and clicking on Network. Next to Configure: select Built-in Ethernet (you can leave the Location: setting as Automatic). 3.
User’s Guide Section 4 – Troubleshooting Introduction This section describes procedures for troubleshooting problems you may encounter with the print server, and is divided into the following sections: Installation Problems Intermittent Problems Protocol-Specific Troubleshooting If you have followed the steps in this section and you believe that you have a defective print server, then please refer to Section 5 – Where to Get Help for information on returning defective products.
User’s Guide If the self-test page prints successfully but you cannot print a job or you get distorted printouts, make sure the printer is set for the correct Page Description Language. Most new printers support AUTO mode, which means that they will automatically switch between PCL and PostScript. However, older printers like the LaserJet II, LaserJet III, and LaserJet IIISi require that the printer be set to the desired language through the printer control panel.
User’s Guide Troubleshooting Network Configuration Problems If you are using TCP/IP, make sure that your computer and the print server are on the same IP segment or can reach each other with a PING command from the host. The IP address you assign to the print server must be on the same logical network as your host computers (e.g., if your computer has an IP address of 192.189.207.3, the print server should have an IP of 192.189.207.
User’s Guide Troubleshooting Wireless Configuration Problems Make sure your computer’s wireless adapter and/or access point is configured properly and note the settings, paying special attention to the wireless mode, SSID or network name, WEP or security, and IP address settings so you can configure your print server to the same wireless settings. Make sure the radio mode is configured properly for 802.11g if auto mode is not connecting properly.
User’s Guide Section 5 – Where to Get Help Silex offers several customer support options to assist you in the event you experience difficulties with your print server, including telephone support, repair services, and warranty. The worldwide web site provides a quick and easy way to answer many common technical questions. It includes a wide variety of technical support tips, as well as copies of product manuals, product literature, and firmware load images. The web site is located at www.silexamerica.com.
User’s Guide Returning Products If you need to return a product for any reason (failures, incorrect shipments, etc.), follow the steps below: 1. Contact the Technical Support group at (801) 748-1199 to request a Return Goods Authorization (RGA) number. 2. Be prepared with the serial number of the unit you are returning. You will be asked for the serial number to verify warranty coverage. Please record these serial numbers in the space provided below for future reference.
User’s Guide Appendix A – Safety and Regulatory Notices Information for United States Users: SX-200 This equipment has been tested and found to comply within the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
User’s Guide Declaration of Conformity (FCC): SX-200 According to 47CFR, Part 2 and 15 for Class B Personal Computers and Peripherals; and/or CPU Boards and Power Supplies used with Class B Personal Computers: We: Located at: Silex Technology America, Inc. 157 West 7065 South Salt Lake City, UT 84047, USA Declare under sole responsibility that the product identified herein, complies with 47CFR Part 2 and 15 of the FCC rules as a Class B digital device FOR HOME OR OFFICE USE.
User’s Guide Information for European Users: SX-200 The SX-200 print server is in compliance with the Class B Information Technology Equipment requirements and other relevant provisions of European Directive 1999/5/EC. The limits for Class B equipment were derived for typical residential environments to provide reasonable protection against interference with licensed communications devices. The internal function is a radio device using the 2.4 GHz frequency band (2.400GHz - 2.4845 GHz) and 5.
User’s Guide Declaration of Conformity (FCC): SX-215 Silex Technology America, Inc, located at 157 West 7065 South, Salt Lake City, Utah 84047, USA, (801) 748-1199 declares this equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
User’s Guide To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment that is installed outdoors is subject to licensing. Document #40181-420 Rev.
User’s Guide Appendix B – Updating Firmware Loading New Firmware (Using the TCP/IP Update Utility) The silex print server’s internal firmware can be easily updated as updates become available. Please visit the silex web site for more information on how to download the latest firmware updates at www.silexamerica.com. Updating the print server’s firmware will not change any user-defined configuration options. 1. Run the Update utility for TCP/IP. The About Update for TCP/IP window will be displayed.
User’s Guide 3. Verify that the file(s) are correct, and then click on OK. The utility will start searching for qualified print servers present on the network. 4. When the search process is complete, click on OK to continue. A list of discovered devices will be displayed. Document #40181-420 Rev.
User’s Guide 5. Select the desired print server to be upgraded, click on the green icon, or click on UPDATE START. The firmware update process will begin automatically as soon as the print server is ready. 6. When the print server is ready, the firmware upgrade will begin. The IP address of the print server as well as the file you are loading will be displayed. Document #40181-420 Rev.
User’s Guide 7. The update log will be displayed when the update process is finished. Click on Close to continue. Loading New Firmware (Macintosh OS-X) NOTE: To upgrade your print server’s firmware from operating systems other than Windows or Macintosh, refer to the Print server Administrator’s Guide (provided in PDF format on the Print Server Installation CD). 1. If you are using the Macintosh OS-X operating system, download the firmware file to your desktop. 2.
User’s Guide Command console access information silex servers support a sophisticated command-line oriented console for configuration and management. The console includes some features that are not available through other configuration methods. The console can be accessed via TELNET, the server’s serial port (if applicable), or through the ADMIN web page using the web browser interface. The general configuration procedure is the same regardless of which method is used.
User’s Guide Network Commands This group of commands configures network parameters SH NW Displays summary network information sample output: WiFi Mode = INFRASTRUCTURE WiFi SSID: silex Speed = 11 Regulatory Domain = 704 WiFi FW Ver = 1F 1.7.
User’s Guide SH NW ENC Shows the wireless encryption mode sample output: WiFi encryption is Disabled Note: The deprecated command SH NW WEP will also display this information SET NW KEY# Selects WLAN WEP key entry SET NW KEY# n = 1-4 n (default = 1) SET NW KEYVAL Sets the currently selected WLAN WEP key entry to the hex value given.
User’s Guide SH NW RADio Shows the selected radio mode of operation sample output: Radio mode is 802.11b SET NW SPeed Sets maximum WLAN speed SET NW SPeed n n = 1,2,5.5,6,9,11,12,18,24,48,54 (default = 54) SH NW SPEED Show the maximum wireless data speed in megabits per second sample output: Speed = 11 SET NW SSid Sets WLAN SSID SET NW SSid User defined (default = printer) CL NW SSid Clears the SSID value so the server will connect to any AP.
User’s Guide CL NW BSsid Document #40181-420 Rev.
User’s Guide SH NW STATS Show the network I/O statistics sample output: WiFi statistics: TX Unicast frames: 0 TX Multicast frames: 0 TX Fragments: 0 TX Unicast octets: 0 TX Multicast octets: 0 TX Deferred: 0 TX Single retry frames: 0 TX Multiple retry frames: 0 TX Retry limit exceeded: 0 TX Discards: 0 RX Unicast frames: 0 RX Multicast frames: 0 RX Fragments: 0 RX Unicast octets: 0 RX Multicast octets: 0 RX FCS errors: 0 RX Discards no buffer: 0 TX Discards wrong SA: 0 RX Discards WEP undecr: 0 RX Msg in ms
User’s Guide SH NW CERTCN2 Shows the value of the second common name check string sample output: Common name 2 Note: the default for this string is a null (blank) string SET NW CERTEXP Sets EAP Certificate Exponent value SET NW CERTEXP User defined (default = 10001 Hex) SH NW CERTEXP Shows the value of the certificate exponent sample output: 65537 (10001h) Note: The deprecated command SH NW TTEXP will also return this information.
User’s Guide Shows the value of the authentication ID (including realm, if present) sample output: anonymous@somewhere Note: The default realm is a null (blank) string Note: The deprecated command SH NW TTID will also return this information. SET NW PW Sets the password used for the 802.1x EAP authentication, if enabled.
User’s Guide SET NW WPAGROUP Enable or disable WPA group key mode. If enabled, this allows group keys to be used for data link encryption. SET NW WPAGROUP [ENABLE | DISABLE] (default = disabled) SH NW WPAGROUP Shows the state of the allow WPA group keys flag sample output: WPA-GROUP Disabled SET NW WPAPSK Sets the WPA PSK pass phrase or hex key. This value is only used if the authentication mode is WPA-PSK.
User’s Guide This controls whether the radio frequencies are set based on the radio configuration, or information from the access point it connects to. Disabled means the radio defaults are used. Flexible means the access point settings are used if present, but if not the radio default is used. Strict means the access point must provide regulatory frequency information..
User’s Guide { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { { "FR " "FRI" "DE " "DEI" "GR " "HU " "HK " "IS " "ISI" "IN " "IE " "IEI" "IT " "ITI" "JP " "JPI" "JPO" "LU " "LUI" "NL " "NLI" "NZ " "NO " "NOI" "CN " "PT " "PTI" "PL " "SG " "ES " "ESI" "SE " "SEI" "CH " "CHI" "TW " "GB " "GBI" , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , REGDOM_TEXT_FRANCE }, REGDOM_TEXT_FRANCE_INDOOR }, REGDOM_TEXT_GERMANY }, REGDOM_TEXT_GERMANY_INDOOR }, REGDOM_TEXT_
User’s Guide Document #40181-420 Rev.
User’s Guide Parallel Port Commands SH PORT Shows Port parameters sample output: Port *P1 Q-Size 0 Type parallel Attributes BID ACKH NBUF SET PORT Sets Parameters for specified port. The available commands are dependent on the port type. For EasyLAN Wireless Model AW02, the only port available is parallel port P1. SET PORT P1 ACKH Enable or disable pACK handshake (1284 compatible) mode. ECP and Fast Strobe mode must be disabled for compatibility mode to be used.
User’s Guide Enable or disable input wait mode. If enabled, this mode delays polling for input from the printer at the end of a job for one poll period. If disabled, the printer is polled as soon as the last byte in the job is sent to it.. SET PORT P1 INWT [ENable | DIsable] (default = disable) SET PORT P1 NBUF [ENable | DIsable] Enable or disable no buffer mode. If enabled, data is passed directly from the network to the printer without buffering.
User’s Guide This command aborts the currently active job on the port specified. If the remote host is still connected, any further data received will be discarded. CL PORT P1 JOB USB Port Commands SET PORT U1 PSTA Enable or disable PJL status initialization. SET PORT U1 PSTA [ENable | DIsable] (default = disabled) SET PORT U1 NBUF [ENable | DIsable] Enable or disable no buffer mode. If enabled, data is passed directly from the network to the printer without buffering.
User’s Guide SET SNMP JETADmin Enable or disable JetAdmin compatibility SET SNMP JETADmin [ ENable | (default = enabled) DIsable] SET SNMP SETCOMM1 Set Community 1 Name SET SNMP SETCOMM1 (default = “internal?”) SET SNMP SETCOMM2 Set Community 2 Name SET SNMP SETCOMM2 (default = “pass”) SET SNMP CONtact Set system contact string SET SNMP CONtact (default = ) SET SNMP LOCation Set the system location string SET SNMP LOCation (default = ) SH SERIAL Displays
User’s Guide SH SERVEr Shows Server parameters sample output: Serial Server Serial # 9047595 Address: 00-40-17-8A-0E-2B Name: SLX8A0E2B Identification: Network Server Enabled Characteristics: Link DOWN Number: 0 SH SERVEr COunters Shows Server network statistics sample output: Seconds Since Zeroed: Bytes Received: Bytes Sent: Frames Received: Frames Sent: Multicast Bytes Rcv'd: Multicast Bytes Sent: Multicast Frames Rcv'd: Multicast Frames Sent: Frames Sent, Deferred: 163 72950 18726 752 181 64474 2406 6
User’s Guide Service Commands SET SERVI BOT Set beginning of transmission (BOT) string index for service SET SERVI BOT (default = 1) nn SET SERVI EOT Set end of transmission (EOT) string index for service SET SERVI EOT (default = 1) nn SH SERVI STRings [string_num] Defines the BOT and EOT strings used in services. If string_num is provided then the specific string definition and expansion is displayed.
User’s Guide SH SERVI FILters Shows filter settings sample output: # Service Name 1 SLX_FFFFFF 2 BINARY_P1 3 TEXT_P1 CRLF 4 SLXFFFFFF_P1_4 5 SLXFFFFFF_P1_5 6 SLXFFFFFF_P1_AT Filter 0: No Filter 0: No Filter 1: Text Substitution m= LF, r= 0: No Filter 0: No Filter 4: PostScript Tagged Binary SET SERVI FMS Set filter 1 (text replacement filter) match string index. If the index is zero, the default string of (line feed) is used.
User’s Guide SET SERVI PRIority Set priority for service if multiple service try to transmit data at the same time. Higher priority services are serviced first. SET SERVI PRIority nn (default = 10) SH SERVI PRI [service_num] This shows the priority of a specific service. If service_num is not provided, the priority of all services is listed. SET SERVI RECeive Set receive only mode for a service.
User’s Guide String Commands These commands configure strings used with services and service filters. SET STRing Set service string table entry. (Note, String 1-11 can not be set or changed). SET STRing ”value” CL STRing Clears the service string table entry. CL STRing SH STRing [string_num] Defines the BOT and EOT strings used in services If string_num is provided then the specific string definition and expansion is displayed.
User’s Guide SET IP ACcess Allow or disallow access to a block of remote addresses SET IP ACcess [EN | DI | ALL] aa.bb.cc.dd {MAsk ee.ff.gg.hh] (default = empty list) SET IP RANge Allow or disallow access to a range of remote addresses SET IP RANge [EN | DI | ALL] aa.bb.cc.dd {MAx ee.ff.gg.hh] (default = empty list) SH IP ACcess Display current access list settings Sample output: All hosts permitted access SET IP ADdress Set server IP address SET IP ADdress aa.bb.cc.dd (default = 192.0.0.
User’s Guide SET IP CHKSUM Enable or disable verification of the IP checksum on received packets SET IP CHKSUM [ENable | DIsable] (default = enable) SET IP BOot Number of tries for each enabled IP boot method, if not set to STATIC SET IP BOot n (default = 3) SET IP ENable Enable or disable all IP based protocols SET IP [ENable | DIsable] (default = enable) SET IP FTIme If enabled, the IP timeout is measured in seconds. If disable, the IP timeout is in minutes.
User’s Guide SET IP LPD Enable or disable the LPD protocol SET IP LPD [ENable | DIsable] (default = enable) SET IP MEthod Set method of getting IP address SET IP MEthod [ AUTO | BOOTP | RARP | DHCP | STATIC ] (default = AUTO) SET IP PIng Send IP ping packets to test connection to remote host. SET IP PIng aa.bb.cc.
User’s Guide SET IP SUbnet Set the IP subnet mask SET IP SUbnet aa.bb.cc.dd (default = 0.0.0.
User’s Guide SH IP Shows TCP/IP related Parameters sample output: IP is enabled IP address 192.0.0.192 Subnet mask 0.0.0.0 IP Gateway 0.0.0.0 (set manually) LPD banner disabled LPD retries are disabled Service xxxxxx_S1_A xxxxxx_S1_B Document #40181-420 Rev.
User’s Guide Firmware Update These commands set up the unit for performing an update of the server firmware. SET LOAd ENable If enabled, the firmware performs a soft reset and enters the server boot program after the next EXIT command. This command should not be used with the Serial Server. It remains in the firmware for diagnostic use. SET LOAd (ENable | DIsable ] (default = disable) SET LOAd HOst Set the node name of the Netware boot host.
User’s Guide SH LOAd Shows the firmware update parameters sample output: Firmware load is disabled Load Host IP = 0.0.0.0 Software file = xxxx.bin Load Host Name = Document #40181-420 Rev.
User’s Guide Other Commands SET DEFAULT Set parameters to factory defaults EXIT This command exits the current configuration console session. EXIT SH FATal Shows fatal error log (if there’s any) sample output: No saved errors CL FATal Clears the fatal error log SH FREE Shows the amount of heap and configuration memory available sample output: 2 bytes of heap available Index 2, 6320 bytes 6320 bytes configuration memory available HElp This is for getting help on the console commands.
User’s Guide INIT This command instructs the server to do a soft reset when the next exit command is executed. INIT SET PAssword Sets the server access (read) password SET PAssword (default = “ACCESS”) SET POWERON Sets Power on delay SET POWERON default == 0 (no delay) SH POWERON Displays Power on delay in seconds SET PROTect Sets update password to the string given. SET PROTECT (default = ) CL PROTect Sets update password to .
User’s Guide SH TEst Sends the configuration data via ASCII to the serial port UNPROTECT If an update password has been defined (SET PROTECT), this command is used to enter the password to allow configuration items to be modified. After entering this command, the server will prompt for the update password. If entered properly, the user will then be able to execute SET commands to modify the server configuration. This lasts only until the console session is terminated with an EXIT command.
User’s Guide SET NETW POlling Set Queue polling time in seconds SET NETW POlling n (default = 4) SET NETW QServer Set QServer mode on service SET NETW QServer ON SET NETW REscan Rescan Netware servers for new queues SET NETW REscan SET NETW SErver Enable or disable access to a server SET NETW SErver [ENable | DIsable] CL NETW SErver Removes the specified Netware Server CLear NETW SErver Document #40181-420 Rev.
User’s Guide SH NETWare Shows Netware Parameters sample output: Netware is Enabled Enabled frame types AUTO Queue polling frequency is 4 seconds Advertising frequency is 60 seconds Queue Servers PR1 * Frame type Ethernet II IEEE 802.2 IEEE 802.
User’s Guide Set POP3 Mailbox from which to fetch email jobs. SET POP3 NAme (default = ) SET POP3 PAssword POP3 Mailbox password SET POP3 PAssword (default = ) SET POP3 TImeout Set POP3 Message timeout in minutes SET POP3 TImeout nn (default = 120 min) SET SMTP ADdress SMTP Server IP address SET SMTP ADdress aa.bb.cc.dd (default = 0.0.0.0) SET SMTP ENable Enable/Disable SMTP Protocol SET SMTP [ ENable | DISable ] (default = enabled) Document #40181-420 Rev.
User’s Guide SH POP3 Shows POP3 Parameters sample output: Internet Printing Configuration: POP3 POP3 POP3 POP3 POP3 POP3 POP3 POP3 POP3 POP3 POP3 SMTP SMTP SMTP SMTP SMTP SMTP Server 0.0.0.0 Mailbox Polling 30 seconds Timeout 120 minutes Total Messages 0 Total Connects 0 Connect Failures 0 Connections Lost 0 User Failures 0 Password Failures 0 Total I/O Errors 0 Server 0.0.0.0 Total Messages 0 Total Connects 0 Connect Failures 0 RecdFrom Failures 0 SentTo Failures 0 SH SMTP Shows SMTP Parameters.
User’s Guide SH DLC Shows DLC Parameters sample output: DLC is Enabled DLC timeout 30 seconds SET NetBEUI ENable Enable/Disable NetBEUI Protocol SET NETBEUI [ ENable | DISable ] (default = enable) SET NETBIOS DOMain Set the NETBIOS domain name SET NETBIOS DOMain (default = ) SET NETBIOS MEthod Set method of getting WINS server address SET NETBIOS MEthod [ AUTO | STATIC ] (default = AUTO) SET NETBIOS PRimary Set the IP address of primary WINS server SET NETBIOS PRimary aa.bb.cc.
User’s Guide (default = enabled) SET APPletalk ZOne Configures the Appletalk Zone for this server SET APPletalk ZOne (default = none) Document #40181-420 Rev.
User’s Guide Wireless Security Configuration silex products support various methods of authentication and encryption to ensure compatibility with wireless security depoyments. This document describes how to configure wireless security on silex print servers and device servers. silex offers a variety of ways to configure the security parameters, including the ExtendView utility for Windows systems, a built-in web browser interface, and a command line console (described at the end of this document).
User’s Guide • WPA2-WPA uses CCMP for pair-wise encryption, but allows TKIP for group encryption. Key Selection If WEP encryption is selected, and the authentication mode is not an EAP (802.1x) mode, select the desired WEP key to be used, one through four. WEP Key These fields are ignored unless the encryption mode is 64 or 128 bit WEP. Enter up to 10 hexadecimal digits for 64 bit WEP, or 26 hexadecimal digits for 128 bit WEP.
User’s Guide WPA Group Key If the WPA Group Key mode is enabled, then group keys may be used for data link encryption. The default is disabled. -------------------------------------------------------------------------------Command Line Console Configuration Go to the command prompt on your PC and type TELNET ipaddress (where ipaddress is the IP Address configured in the print server). You should get a # prompt, type in the password (default is ACCESS, this will not echo on your screen as you type it).
User’s Guide SET NW ENC [DIsable | 64 | 128 | WPA | WPA2 ] (default = Disable) SH NW ENC Shows the wireless encryption mode sample output: encryption is Disabled SET NW KEY# Selects WLAN WEP key entry SET NW KEY# n n = 1-4 (default = 1) SET NW KEYVAL Sets the currently selected WLAN WEP key entry to the hex value given.
User’s Guide SH NW SPEED Show the maximum wireless data speed in megabits per second sample output: Speed = 11 SET NW SSid Sets WLAN SSID SET NW SSid User defined (default = printer) CL NW SSid Clears the SSID value so the server will connect to any AP. CL NW SSid SET NW BSsid Sets WLAN BSSID (connect to a specific access point’s mac address) SET NW BSsid User defined (MAC Address) CL NW BSsid Clears the BSSID value so the server uses just SSID and not a specific AP.
User’s Guide SH NW STATS Show the network I/O statistics sample output: WiFi statistics: TX Unicast frames: 0 TX Multicast frames: 0 TX Fragments: 0 TX Unicast octets: 0 TX Multicast octets: 0 TX Deferred: 0 TX Single retry frames: 0 TX Multiple retry frames: 0 TX Retry limit exceeded: 0 TX Discards: 0 RX Unicast frames: 0 RX Multicast frames: 0 RX Fragments: 0 RX Unicast octets: 0 RX Multicast octets: 0 RX FCS errors: 0 RX Discards no buffer: 0 TX Discards wrong SA: 0 RX Discards WEP undecr: 0 RX Msg in ms
User’s Guide sample output: Common name 2 Note: the default for this string is a null (blank) string SET NW CERTEXP Sets EAP Certificate Exponent value SET NW CERTEXP User defined (default = 10001 Hex) SH NW CERTEXP Shows the value of the certificate exponent sample output: 65537 (10001h) Note: The deprecated command SH NW TTEXP will also return this information. SET NW CERTKEY Sets EAP Root Key SET NW CERTKEY User defined SET NW ID Sets Authentication User ID.
User’s Guide Sets EAP Inner-Authentication protocol SET NW INAP [PAP|MSCHAP_V2] (default = PAP) SH NW INAP Shows the selected inner authentication mode sample output: Authentication protocol = PAP Note: the deprecated command SH NW TTAP will also return this information. SET NW REALM Sets the realm portion of the 802.1x EAP authentication ID This may also be set with the ID command. SET NW REALM (default = ) SH NW REALM Shows the realm associated with the authentication ID, if any.
User’s Guide SET NW WPAPSK Sets the WPA/WPA2 PSK pass phrase or hex key. This value is only used if the authentication mode is WPA-PSK. The argument to this command is either a pass phrase of 8-63 characters, or exactly 64 hex characters representing the 256 bit PSK value. SET NW WPAPSK (default = “silex”) SET NW WPATRACE Sets the WPA trace level. note: this command is for diagnostic purposes only, and should not normally be used as the trace can affect performance. A value of 0 disables the trace.