Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 5: Appendix: Pin assignments
65
Pin assignments
RS-422
RJ45 connector
1 8
1 8
IN OUT
Pin No. Function
1 TX–
2 TX+
3 RX–
4 GND
5 GND
6 RX+
7 N.C.
8 N.C.
Pin No. Function
1 RX–
2 RX+
3 TX–
4 GND
5 GND
6 TX+
7 N.C.
8 N.C.
Contact terminal block
1 2 3 4 5
VISCA RS-422
6 7 8 9
Pin No. Function
1 RXD OUT–
2 RXD OUT+
3 TXD OUT–
4 TXD OUT+
5 GND
6 RXD IN–
7 RXD IN+
8 TXD IN–
9 TXD IN+
Connecting cable example
When connecting BRC-X1000/H800
1 9
1 8
Shield
RM-IP10
1 N.C.
2 N.C.
3 N.C.
4 N.C.
5 GND
6 RX–
7 RX+
8 TX–
9 TX+
Camera
1 TX–
2 TX+
3 RX–
4 GND
5 GND
6 RX+
7 N.C.
8 N.C.
Notes
Connect the GNDs of both devices together to stabilize
the voltage level of the signal.
When preparing cables, use network cables of category 5e
or more. Use cables equivalent to or higher than shielded
twisted pair cables.