Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 2: Connection & Basic Settings: Connection with MSU-1000/3000 series
36
Return to the Config TOP screen, select MSU >Network >TCP/IP, then adjust any necessary
network settings.
Configuration example
IP address : 192.168.0.50
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.254
After input is complete, press [Set] to apply settings.
Return to the Config TOP screen and select Config >MSU >Network >CNS.
Turn [MCS] on and press [Set] on the right side of the screen.
Next press [Edit], then select Master and enter the MSU-1500/3500 IP address.
IP address example: 192.168.0.50
Press [Set].
This concludes MSU-1500/3500 configuration.
4. Configure the RCP connection.
[Connecting RCP-3100]
This description is for a connection by the following network settings.
* The following settings can also be configured in the Web menu. For information on Web menu settings and RCP-3100
details, see the RCP-3100 Operating Instructions.
RCP-3100
IP address : 192.168.0.20
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.254
Press and hold the CONFIG button to start configuration mode.
The CONFIG button LED remains lit in configuration mode.
Perform operations a. to d. for all items listed on the front.
a. Set the master gain display window to the number of the item to set using the master gain
selection buttons.
b. Set the CC (color temperature conversion) filter display window to the number of the item to
set using the CC filter selection buttons.
c. Display the desired setting in the adjustment display window by turning the adjustment knob.
d. Press the SAVE button to apply the setting.
Adjustment knob
Adjustment display
window
Master gain selection
buttons
Master gain display
window
SAVE button
CONFIG button
CC (color temperature
conversion) filter selection
buttons
CC (color temperature
conversion) filter display
window
Setting item Master gain
display window
number
CC (color
temperature
conversion)
filter display
window
number
Adjustment display
window display
(sample address
shown)
1 1st block of RCP IP address 02 1 192 (192.168.0.20)
2 2nd block of RCP IP address 2 168 (192.168.0.20)
3 3rd block of RCP IP address 3 0 (192.168.0.20)
4 4th block of RCP IP address 4 20 (192.168.0.20)
5 1st block of RCP subnet mask 03 1 255 (255.255.255.0)
6 2nd block of RCP subnet mask 2 255 (255.255.255.0)
7 3rd block of RCP subnet mask 3 255 (255.255.255.0)
8 4th block of RCP subnet mask 4 0 (255.255.255.0)
9 1st block of RCP default gateway 04 1 192 (192.168.0.254)
10 2nd block of RCP default gateway 2 168 (192.168.0.254)
11 3rd block of RCP default gateway 3 0 (192.168.0.254)
12 4th block of RCP default gateway 4 254 (192.168.0.254)
13 Connection mode (CNS) 01 – (Setting not
required)
2 (MCS mode)
Continued on the following page