Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 2: Connection & Basic Settings: Connection with MSU-1000/3000 series
35
Connection with MSU-1000/3000 series
Devices
Remote camera with
interchangeable lens
ILME-FR7
Remote camera BRC-X1000/H800/X400
Remote control panel RCP-3500/3501/3100/1500/1501/1530
Master setup unit MSU-1000/1500/3000/3500
Other Commercially available switching hubs, setup PC
What you can do
You can connect to ILME-FR7, BRC-X1000, and BRC-H800 in MCS Mode via network connection from a
Sony-brand remote control panel and master setup unit. MCS Mode is used to link RCP and MSU in a
multi-camera environment.
Setup instructions
This connection procedure uses ILME-FR7, BRC-X1000/H800/X400, RCP-3500/3100/1500, and
MSU-1500/3500 for explanation purposes. See the applicable operation manuals for procedures on how
to configure other devices.
1. Connect the devices using the diagram on the left as a reference, then turn them on.
2. Set the IP address of each camera to connect to.
See “Auto IP address setting from RM-IP500” (page 19) and “IP address setting from RM-IP Setup
Tool” (page 21) for instructions on how to set IP addresses.
3. Configure MSU-1500/3500 network settings.
Press the MSU-1500/3500 menu operation block CONFIG button, then from the screen select
MSU > Security, and turn Engineer Mode on.
Engineer Mode is turned on and the button is lit orange.
Continued on the following page
Switching hub
RCP-1500/1501 RCP-3100 RCP-3500/3501
Setup PC
MSU-1500/3500
BRC-X1000 ILME-FR7
Remote control signal: Network cable (Cat 5e or higher)
Signal flow