Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 2: Connection & Basic Settings: Connection with RCP-3500/3100/1500 series
34
[Connecting RCP-3500/1500]
In the RCP-3500/1500 MENU screen, select Config >RCP >Security, then turn Engineer Mode
on.
Engineer Mode is turned on and the button is lit orange.
Return to the MENU TOP screen, then select Config >RCP >Network >TCP/IP and configure the
necessary network settings.
Configuration example
IP address : 192.168.0.20
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.254
After input is complete, press [Set] to apply settings.
Return to the RCP-3500/1500 MENU screen TOP, select Config >RCP >Network >CNS, then turn
Bridge Mode on.
Press [Set] on the screen.
Next press [Edit], enter the IP address of the camera you want to operate, and finally press [Set].
If the connection is successful, the shutter speed, etc. of the connected camera appears in the
panel.
Precautions
Update the BRC-X1000/H800 software to v2.0 or later before use.
Update the ILME-FR7 software to v1.10 or later before use.
The RCP-3500/3100/1500 series requires a PoE power supply (IEEE802.3af). The ILME-FR7 requires a
PoE++ power supply (IEEE802.3bt Type 4 Class 8) or 19.5 V DC power supply. The BRC-X1000/H800
requires a PoE+ power supply (IEEE802.3at) or 12 V DC power supply. Use a compatible switching hub.
CNA-1 (sold separately) is required for BRC-H900 to RCP connection. See the HZC-BRCN1 operation
manual for further details.