Remote Camera System Guide

000
Chapter 2: Connection & Basic Settings: Connection with RCP-3500/3100/1500 series
33
3. Configure the RCP connection.
The configuration procedure differs for the RCP-3100 and RCP-3500/1500. See the procedures for
each product.
[Connecting RCP-3100]
This description is for a connection by the following network settings.
* The following settings can also be configured in the Web menu. For information on Web menu settings and RCP-3100
details, see the RCP-3100 Operating Instructions.
RCP-3100 Camera connected to RCP-3100
IP address : 192.168.0.20
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.254
IP address : 192.168.0.100
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.254
Press and hold the CONFIG button to start configuration mode.
The CONFIG button LED remains lit in configuration mode.
Perform operations a. to d. for all items listed on the front.
a. Set the master gain display window to the number of the item to set using the master gain
selection buttons.
b. Set the CC (color temperature conversion) filter display window to the number of the item to
set using the CC filter selection buttons.
c. Display the desired setting in the adjustment display window by turning the adjustment knob.
d. Press the SAVE button to apply the setting.
Adjustment knob
Adjustment display
window
Master gain
selection buttons
Master gain display
window
SAVE button
CONFIG button
CC (color temperature
conversion) filter
selection buttons
CC (color temperature
conversion) filter
display window
Setting item Master gain
display window
number
CC (color
temperature
conversion)
filter display
window
number
Adjustment display
window display
(sample address
shown)
1 1st block of RCP IP address 02 1 192 (192.168.0.20)
2 2nd block of RCP IP address 2 168 (192.168.0.20)
3 3rd block of RCP IP address 3 0 (192.168.0.20)
4 4th block of RCP IP address 4 20 (192.168.0.20)
5 1st block of RCP subnet mask 03 1 255 (255.255.255.0)
6 2nd block of RCP subnet mask 2 255 (255.255.255.0)
7 3rd block of RCP subnet mask 3 255 (255.255.255.0)
8 4th block of RCP subnet mask 4 0 (255.255.255.0)
9 1st block of RCP default gateway 04 1 192 (192.168.0.254)
10 2nd block of RCP default gateway 2 168 (192.168.0.254)
11 3rd block of RCP default gateway 3 0 (192.168.0.254)
12 4th block of RCP default gateway 4 254 (192.168.0.254)
13 Connection mode (CNS) 01 – (Setting not
required)
1 (Bridge mode)
14 1st block of IP address for camera
connection
08 1 192 (192.168.0.100)
15 2nd block of IP address for camera
connection
2 168 (192.168.0.100)
16 3rd block of IP address for camera
connection
3 0 (192.168.0.100)
17 4th block of IP address for camera
connection
4 100 (192.168.0.100)
When settings are complete, press and hold the CONFIG button to exit configuration mode.
Make sure to complete this operation to apply the settings.
When you exit configuration mode, the CONFIG button LED goes out.
When a successful connection is made, the shutter speed, etc., of the connected camera is
displayed on the panel.
Continued on the following page