Remote Camera System Guide

000
Chapter 2: Connection & Basic Settings: Serial connection setting (RS-422/RS-232C)
25
5. Adjust remote controller serial connection settings.
For RM-IP500
From the RM menu, select CONFIG >SERIAL.
The following screen appears.
Select the same BAUD RATE as the camera and change [APPLY] >[NOT EXEC] to [EXEC].
After settings are complete, RM-IP500 automatically restarts.
For RM-IP10
Set DIP switch 1-1 on the bottom to serial connection (ON).
Set the second communication system and third communication system BAUD RATE to the
same as the camera.
Restart RM-IP10 after changing the settings.
Precautions
Use the same settings for the camera and remote controller communication system and BAUD RATE.
RS-422 and RS-232C connections cannot be mixed.
Use a straight network cable for RS-422 connection between RJ-45 connectors.
Serial connection on SRG-360SHE is only supported for a one-on-one communication. Use a network
connection when connecting multiple units.