Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 2: Connection & Basic Settings: Serial connection setting (RS-422/RS-232C)
25
5. Adjust remote controller serial connection settings.
For RM-IP500
From the RM menu, select CONFIG >SERIAL.
The following screen appears.
Select the same BAUD RATE as the camera and change [APPLY] >[NOT EXEC] to [EXEC].
After settings are complete, RM-IP500 automatically restarts.
For RM-IP10
Set DIP switch 1-1 on the bottom to serial connection (ON).
Set the second communication system and third communication system BAUD RATE to the
same as the camera.
Restart RM-IP10 after changing the settings.
Precautions
Use the same settings for the camera and remote controller communication system and BAUD RATE.
RS-422 and RS-232C connections cannot be mixed.
Use a straight network cable for RS-422 connection between RJ-45 connectors.
Serial connection on SRG-360SHE is only supported for a one-on-one communication. Use a network
connection when connecting multiple units.