Chapter 2: Connection & Basic Settings: Serial connection setting (RS-422/RS-232C)
24
Serial connection setting (RS-422/RS-232C)
Devices
Remote camera RS-422 connection BRC-X1000/H800, BRC-H900, BRC-X400, SRG-A40,
SRG-A12, SRG-X400, SRG-X120, SRG-X40UH,
SRG-360SHE, SRG-300SE, SRG-300H
RS-232C connection BRC-H900, SRG-300H, SRG-120DU, SRG-120DH,
SRG-120DS, SRG-XB25
Remote controller RM-IP10 : RS-422/232C
RM-IP500 : RS-422 connection only
What you can do
Serial connection to multiple cameras is possible using VISCA RS-422 or RS-232C. Up to seven units can be
assigned to a single remote controller.
* The cable can be up to 15 m long for RS-232C, and up to 1.2 km long for RS-422.
Setup instructions
1. Connect the devices using the diagram on the left as a reference, then turn them on.
For details on the RS-422/RS-232C connector of each camera, see “RS-422/RS-232C terminal of each
camera” (page 66) in the appendix.
2. Set the camera address using the DIP switch on the camera bottom or rear panel (BRC series only).
When the address is set to 0, the address is automatically set on the camera.
* On BRC-H900 and SRG-300H, use the DIP switch on the bottom or rear panel of the camera to select the
communication system (RS-422/RS-232C).
* Only automatic setting is available for the SRG series camera address.
3. Change the BAUD RATE (9600, 38400) using the DIP switch on the camera bottom or rear panel.
On the SRG-XB25, change BAUD RATE (9600, 38400) using the web settings screen.
4. After using the DIP switch, restart the camera.
EXT SYNC IN
TERMI-
NATION
ON OFF
ON
ON
OFF
LINE OUT
SDI 1
OSD
LAN
SDI 2
2 3 4 5 6 7 81
MONITOR OUTHDMI OUT
SDI 1 SDI 2
IN
SYSTEM
SELECT
IR SELECT
CAMERA SETUP
1 2 3
VISCA RS - 422 OUT
12V
EXT SYNC IN
TERMI-
NATION
ON OFF
ON
ON
OFF
LINE OUT
SDI 1
OSD
LAN
SDI 2
2 3 4 5 6 7 81
MONITOR OUTHDMI OUT
SDI 1 SDI 2
IN
SYSTEM
SELECT
IR SELECT
CAMERA SETUP
1 2 3
VISCA RS - 422 OUT
12V
EXT SYNC IN
TERMI-
NATION
ON OFF
ON
ON
OFF
LINE OUT
SDI 1
OSD
LAN
SDI 2
2 3 4 5 6 7 81
MONITOR OUTHDMI OUT
SDI 1 SDI 2
IN
SYSTEM
SELECT
IR SELECT
CAMERA SETUP
1 2 3
VISCA RS - 422 OUT
12V
RGB/COMPONENT
VISCA RS-422
1 2 3 4 5 6 7 8 9
EXT SYNC IN
IR SELECT
75
1 2 3
OFF ON HD SD
INVISCA RS-232 OUT SDI OUT
DC IN 12V
VIDEO SVIDEO
SDI OUTLAN
1 2
BRBK-IP10
ON
HD
SD
OFF
DATA MIX
RGB/COMPONENT
VISCA RS-422
1 2 3 4 5 6 7 8 9
EXT SYNC IN
IR SELECT
75
1 2 3
OFF ON HD SD
INVISCA RS-232 OUT SDI OUT
DC IN 12V
VIDEO SVIDEO
SDI OUTLAN
1 2
BRBK-IP10
ON
HD
SD
OFF
DATA MIX
Continued on the following page
For RM-IP500 For RM-IP10
Connecting one remote camera to one remote controller
Connecting multiple remote cameras to one remote controller
RM-IP500
RM-IP500
IN IN
OUT OUTIN IN
RM-IP10
RM-IP10
or
RS-422 (RJ-45
connector)
remote
camera
RS-422 (RJ-45
connector)
remote
camera
9-pin terminal
block remote
camera
Up to 7
cameras can
be connected
Remote control signal: Network cable (Cat 5e or higher)
Remote control signal: Network cable modified for terminal block connection (Cat 5e or higher)
Signal flow
RS-422 (RJ-45
connector)
remote
camera
9-pin terminal
block remote
camera
RS-422 (RJ45 connector)
remote camera