Remote Camera System Guide
Table Of Contents
- Table of Contents
- Read This First
- Chapter 1 Application
- Chapter 2 Connection & Basic Settings
- [A] Auto IP address setting from RM-IP500
- [B] IP address setting from RM-IP Setup Tool
- [C] Serial connection setting (RS-422/RS-232C)
- [D] Connection with 4K video switcher
- [E] Fiber connection from BRC-H900
- [F] Tally control from MCX-500
- [G] Connection with AWS-750
- [H] Connection with RCP-3500/3100/1500 series
- [I] Connection with MSU-1000/3000 series
- [J] NDI® | HX connection
- Chapter 3 Products
- Chapter 4 Edge Analytics Appliance Application
- Edge Analytics Appliance Application Configuration
- Usage example of Handwriting Extraction in the classroom
- Usage example of PTZ Auto Tracking in the lecture hall
- Usage example of Close-up by Gesture in the classroom
- Usage example of Chroma key-less CG Overlay in a small-scale studio
- Usage example of Focus Area Cropping at an event space
- Recommended cameras for connection with Edge Analytics Appliance
- Chapter 5 Appendix
000
Chapter 2: Connection & Basic Settings: Auto IP address setting from RM-IP500
20
4.
After setting the IP address, subnet mask, and default gateway, change [APPLY] >[NOT EXEC] to
[EXEC], then press the VALUE button.
The RM-IP500 connection mode is set to IP connection.
5. After confirming that the camera is turned on, press the RM MENU button.
6. From TOP MENU, select AUTO IP SETUP >SETUP IP.
The following screen appears.
7. After specifying the range of IP addresses assigned to the camera, change [SETUP IP] >[NOT EXEC]
to [EXEC], then press the VALUE button.
8. Change [CONFIRM: NO] displayed on the screen to [YES], then press the VALUE button.
After completing IP address settings, “COMPLETE DONE” is displayed on the screen.
The RM-IP500 camera selection block CAMERA button assigned by the camera is lit blue.
9. Press the CANCEL button to return to the TOP MENU and confirm that the selected camera can be
controlled.
The set IP address can be checked in AUTO IP SETUP >CAMERA TABLE.
Precautions
BRBK-IP10 control card (sold separately) is required to control BRC-H900 via IP.
At factory default settings, the IP address of RM-IP500 is 192.168.0.10, and the IP address of the IP
control card is 192.168.0.100. If you do not know the IP address of the camera or IP control card, press
the network reset switch on the back of each device to reset network settings.
When operating the ILME-FR7, use the panel sheet for the ILME-FR7 attached to the RM-IP500.
See the RM-IP500 operation manual for other advanced settings.