User Manual

50
Detailed Menu Description
Chapter 5 Menu Items
[F3] ENABLE Sets the buttons that can be operated on the control panel when the unit is used in
remote control mode.
Disable: Disables all switches and buttons.
Enable: Enables all switches and buttons.
Stp&Ejct (Stop&Eject): Enables only the STOP and Eject buttons.
Lcl map (Local Key Map): Enables the buttons set to Enable in [F4] (MAP).
Unit
[F4] MAP Sets the settings for the local key map. Unit
[F1] STOP Sets whether each of the switches and buttons can be operated during remote
control.
Disable
Enable
Unit
[F2] PLAY Unit
[F3] REC Unit
[F4] EJECT Unit
[F5] JOG Unit
[F6] SHTL Unit
[F7] VAR Unit
[F8] NXT/PRV Unit
[F9] EXECUTE Unit
[F10] EXIT Redisplays the previous menu.
[F5] KEY INHI Sets whether to inhibit the button operations for this unit.
Off
: All buttons are available.
On: The button operation inhibit icon appears on the status bar and the editing
control section, recording/playback section and search control section are
disabled.
Unit
[F9] SYS FRQ Sets the system frequency.
23.98
24
25
29.97
Unit
[F10] SET Applies the setting configured with the [F9] (SYS FRQ) button.
ALT/[F1] PB MODE Sets the playback mode.
Field
: Field playback
Frame: Frame playback
Unit
ALT/[F2] FRZ MODE Specifies the freeze mode and freeze timing for during manual freeze (freeze
control with the control panel, REMOTE 1 to 4 (9-pin) connectors, and GPIO (25-
pin) connector) or auto freeze.
Field1: Freezes the 1st (odd) field.
Field2: Freezes the 2nd (even) field.
Frame: Freezes in frame mode.
Unit
ALT/[F3] FRZ CTRL Sets the freeze operation performed by button operation.
Moment: Performs the freeze operation only while the button is held down.
Latch: Pressing the button performs the freeze operation and pressing the button
again cancels the freeze operation.
Unit
ALT/[F4] ALPHA LV Sets the output level of ALPHA CHANNEL of LINK B output for during 4:4:4 DUAL
LINK output.
White: Outputs the white level.
Black
: Outputs the black level.
Unit
ALT/[F9] ERR DLG Displays error dialogs on the control panel.
Off
On
Unit
Button Indication Setting Target