User Manual
44
Detailed Menu Description
Chapter 5 Menu Items
TC Menu
The TC menu allows you to set all of the items related to
time codes from a single menu.
Button Indication Setting Target
[F1] TCG SRC Selects whether to synchronize the internal time code generator with the external
signal. (see page 27)
preset
ext-LTC
SDI-LTC
SDI-VITC
In
[F2] REGENE Selects the signal to regenerate when the time code generator is in regenerate
mode.
TC & UB
: Regenerates both the time code signal and user bit signal.
TC: Regenerates only the time code signal.
UB: Regenerates only the user bit signal.
In
[F3] RUN Selects the running mode of the time code generator.
Free
: The time code advances when the power is on regardless of the unit’s
operation mode.
Rec: The time code advances only during recording.
In
[F4] DF/NDF Selects the drop frame mode of the time code generator or timer counter.
DF
: Drop frame mode
NDF: Non-drop frame mode
Notes
• This setting is only enabled when the frame frequency of the unit is 29.97 Hz or
59.94 Hz.
• This setting is only valid when [F1] (TCG SRC) is set to “preset.”
I/O
[F5] TM SEL Selects the time data to display on the display. To switch between VITC and LTC,
press the [F10] (TCR SEL) button. (see page 27)
TC
UB
TM1
TM2
I/O
[F7] TM RESET Resets the time counter. I/O
[F8] TM SET Inputs time data. (see page 27) I/O
[F9] TM HOLD The time counter is temporarily stopped while the button is pressed. Out
[F10] TCR SEL Sets the value read by the time code reader.
LTC
VITC
Out
ALT/[F3] TC OUT Sets the time code that is output from the TIME CODE OUT connector during
recording when the internal time code generator is set to a mode for regenerating
the playback time code.
Through
: Outputs the time code signal input from the TIME CODE IN connector as
is.
Regene: Regenerates the time code signal input from the TIME CODE IN
connector before outputting it.
In
ALT/[F4] TM DISP Sets whether TM1 is in 12-hour display mode or 24-hour display mode.
Note
When ±12H is set, the tens digit of the hours value is dropped.
+–12H
24H
I/O