Troubleshooting
Appendix
When a folder in the external storage is being mounted
During front panel operations
Memory(A/B) Error! MEDIA(A/B) CANNOT BE
RESTORED.PLEASE RESTORE IT
USING THE RECORDED EQUIPMENT.
An abnormality has occurred on the memory card,
and data restoration is needed.Perform data
restoration on the device that was used to record to
the memory card in question.
Unknown FS!(A/B) CANNOT USE MEDIA(A/B).
UNSUPPORTED FILE SYSTEM.
The inserted memory card is formatted with an
unsupported file system, or it is not formatted.
Format the memory card, or exchange the memory
card for one that is formatted with a file system
supported by this unit.
R/W Limit(A/B) MEDIA REACHED REWRITE LIMIT.
CHANGE MEDIA(A/B).
The memory card has reached its lifetime rewriting
limit.
Copy clips on the memory card to other media as
required, and then exchange the memory card.
Note
If you continue to use the memory card, normal
recording and playback may not be possible.
Over DUR!(A/B) EXCESSIVE DURATION IS IN
MEDIA(A/B).
A clip with a duration that exceeds 24 hours is
recorded on a memory card.
This memory card cannot be used.
Under Repair of Media
(A/B)
MEDIA (A/B) IS BEING REPAIRED. Automatic repair for the management area of the
memory card is in progress.
Wait until the automatic repair is complete.
Repair Failed (A/B) REPAIR FAILED. The memory card is damaged, and recording and
playback are not possible.
Replace the memory card.
Alarm message in status
display area
Alarm message in video monitor
screen
Description/action
USB DRV Error! USB DRIVE CANNOT BE
RESTORED.PLEASE RESTORE IT
USING THE RECORDED EQUIPMENT.
The operation target folder in the external storage
needs data restoration.Perform data restoration on
the device that was used to record to the external
storage in question.
USB DRV needs
Restoring.
MEDIA ERROR.USB DRIVE NEEDS TO
BE RESTORED.
An abnormality has occurred on the operation target
folder in the external storage, and data restoration is
needed.Perform data restoration on the external
storage in question or format it.
Over DUR!(USB DRV) EXCESSIVE DURATION IS IN USB
DRIVE.
The total length of the clips stored in the operation
target folder in the external storage exceeds 24
hours.This operation target folder cannot be used.
Alarm message in status
display area
Alarm message in video monitor screen Description/action
Alarm message in status
display area
Description/action
KEY INHI.! This appears when the KEY INHI switch is “ON”.
Set the KEY INHI switch to “OFF”.
Not Open Clip! This appears when a clip operation is attempted with no clip selected.
Select a clip in the clip list screen and try the operation again.
Clip Top! During playback, this appears if you execute a reverse search when the unit is stopped at the first
frame of a clip. To move to another clip, press the PREV, NEXT, SHIFT + PREV, or SHIFT + NEXT
button, or perform a thumbnail search.
Clip End! During playback, this appears if you execute a forward search when the unit is stopped at the last
frame of a clip. To move to another clip, press the PREV, NEXT, SHIFT + PREV, or SHIFT + NEXT
button, or perform a thumbnail search.