User Manual

25
Connections and Settings
Chapter 3 Preparations
Editing Control Unit Settings
When connecting an editing control unit (BVE-700/700A/
2000) to use with this unit, set VTR constants as follows.
.
HDW-M2000 (recorder) settings BVE-700/700A (editing control unit) setting Settings on this unit
REMOTE 1 (9P) button: Lit SYNCHRONIZE menu:OFF Remote control switch:
REMOTE (see page 10)
REF.VIDEO INPUT connector 75 Ω termination
switch: OFF
Setup menu item 214
REMOTE INTERFACE:
9PIN
Audio selection function switching button
INPUT button: HDSDI
Function menu HOME >F1 (VID. IN): SDI
Function menu page 1 >F1 (TCG): INT
Function menu page 1 >F2 (PR/RGN): PRESET
Function menu page 1 >F3 (RUN): FREE
System frequency VTR constant
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
59.94i/59.94P/29.97P A0 B1 00 96 07 07 03 80 0A 07 FE 00 80 5A FF 5A
50i/50P/25P A1B1007D070703800A07FE00804CFF4B
23.98P A2 B1 00 78 07 07 03 80 0A 07 FE 00 80 48 FF 48