SIGNAL PROCESSING UNIT PFV-SP3300 BACKUP POWER SUPPLY UNIT HK-PSU03 INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher (PFV-SP3300) Serial No.
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden.
Table of Contents Manual Structure Purpose of this manual ........................................................................................ 2 (E) Related manuals ................................................................................................... 2 (E) 1. Installation 1-1. 1-2. 1-3. 1-4. 1-5. 1-6. 1-7. 1-8. Operating Environment ......................................................................... 1-1 (E) Power Supply ............................................................
Manual Structure Purpose of this manual This manual is the installation manual of Signal Processing Unit PFV-SP3300 and its Backup Power Supply Unit HK-PSU03. This manual is intended for use by trained system and service engineers, and describes the information for installation of the unit. n The functions and specifications of HK-PSU03 and PFV-SP3300’s power supply unit are equal. This manual uses “Power Supply Unit” for HK-PSU03 and PFVSP3300’s power supply unit.
Section 1 Installation 1-1. Operating Environment Operating temperature Performance temperature Humidity Mass: PFV-SP3300 HK-PSU03 +5 dC to +40 dC +10 dC to +35 dC 10 to 90 % (No condensation) Approx. 10 kg (Without the optional unit and board) Approx. 2 kg . To prevent overheating of PFV-SP3300, ensure that there is good air circulation around the unit. . Do not put the unit in a place subject to excessive lamp smoke, vapor, moisture, or dust. c Install in a stable location.
1-3. Installation Space 1-3. Installation Space m . Do not block the ventilation holes of the unit. . Both of the front and rear sides must be at least 20 cm away from the walls for ventilation and maintenance. 7 61 ø26 380 550 26 The outer dimensions of PFV-SP3300 are as shown here: 440 17.5 132.
1-4. Installing/Removing Optional Power Supply Unit 1-4. Installing/Removing Optional Power Supply Unit w Before installing the backup power supply unit HK-PSU03 in PFV-SP3300, set the power switch of HK-PSU03 to the “O” position (OFF). Otherwise, deterioration of a connector which connects HK-PSU03 to PFV-SP3300 may cause a fire. 3. Make sure that the power switch of the backup power supply unit HK-PSU03 is set to the “O” position (OFF). 4.
1-5. Installing Optional Board 1-5. Installing Optional Board The optional board can be installed in any empty slot of PFV-SP3300. Installing Main Board (Front side) 1. Turn off the power switches of PFV-SP3300. n Turn off both of the power switches when the backup power supply unit is installed. 2. Remove the front panel. (Refer to Section 1-4.) 3. Remove the four screws and remove the board retainer. 4.
1-5. Installing Optional Board Installing Connector Panel (Rear side) The connector panel must be installed to the slot which contains the main board. 1. Remove the two screws and remove the blank panel of the slot which contains the main board. n Keep the removed blank panel and two screws. B 3x5 B 3x5 Blank panel 2. Connect the connector panel to the MB-915 board. 3. Secure the connector panel with the two screws.
1-6. Rack Mounting 1-6. Rack Mounting PFV-SP3300 can be mounted on a 19-inch standard rack for use. Mount PFV-SP3300 on the rack properly in the procedure below using a specified rack mounting kit. n Install a ventilating fan in the rack to prevent the increase in the temperature inside a rack when multiple units are put in one rack. 1-6-2.
1-6. Rack Mounting n The maximum depth of an adaptor is 750 mm. The minimum depth of an adaptor is 595 mm. 3. Firmly lay the right and left adaptors in the rack with the specified six screws. (Following figure is case of left side.) 7. Fix the unit to the rack with the specified screws. RMM-10 Front 31.75 3U B 4x10 B 5x12 Rear B 4x10 31.75 B 5x12 4. Fasten the length adjustment screws which are loosened in step 2. 5. Remove the front panel. (Refer to Section 1-4.) 6.
1-7. Matching Connector/Cable 1-8. Signal Inputs/Outputs 1-7. Matching Connector/Cable When external cables are connected to the connectors on the PFV-SP3300 rear panel, the hardware listed below (or the equivalent) must be used. PFV-SP3300 side connector Matching connector/cable Print on Connector type Connector type Sony Part Number REMOTE REF IN A/B BNC, 75Z BNC, 75Z Belden 1694 coaxial cable 1-569-370-12 – STATUS OUT D-sub Mini 15-pin, Female D-sub Mini 15-pin, Male – 1-8.
Section 2 Service Overview 2-1. Cleaning the Filter w Be sure to turn off the power switch and disconnect the power cord from the outlet before starting any work. c . The temperature inside the unit increases if dust adheres to the filter and the ventilation holes are blocked. Touching inside the unit while it is hot may result in burn injuries. . Clean the filter on the rear of the front panel periodically because the filter tends to gather dust (once every two months). 2-2.
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation.
HK-PSU03 (SY) PFV-SP3300 (SY) J, E 3-204-888-01 Sony Corporation Communication System Solutions Network Company Printed in Japan 2000.