SWITCHER PROCESSOR PACK MVS8000SF-C MULTI FORMAT SWITCHER PROCESSOR MVS-8000SF HK-PSU04 MKS-8110HD MKS-8110SD MKS-8110M MKS-8160HD MKS-8160SD MKS-8160M MKS-8170HD MKS-8170SD MKS-8170M MKS-8210HD MKS-8210SD MKS-8210M MKS-8440HD MKS-8440SD MKS-8440M MKS-8210K1 MKS-8440K1 MKS-8420M INSTALLATION MANUAL 1st Edition (Revised 2)
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden.
Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit. 2. Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection. 3.
Table of Contents Manual Structure Purpose of this manual .............................................................................................. 3 Related manuals ......................................................................................................... 3 Contents ..................................................................................................................... 3 1. Installation 1-1. 1-2. 1-3. 1-4. 1-5. 1-6. 1-7. 1-8. 1-9. Operating Environment ................
Manual Structure Purpose of this manual This manual is the installation manual of Switcher Processor Pack MVS8000SF-C and their optional boards and units. This manual is intended for use by trained system and service engineers, and describes the information on installing the MVS8000SF-C. Related manuals The following manuals are prepared for MVS8000SF-C and their optional boards and units. . Operation Manual (Supplied with MVS8000SF-C) This manual describes the application and operation of MVS8000SF-C. .
Section 1 Installation 1-1. Operating Environment Operating guaranteed temperature : +5 dC to +40 dC Performance guaranteed temperature : +10 dC to +35 dC Operating humidity : 10 % to 90 % (relative humidity) Storage temperature : _20 dC to +60 dC Mass : Approx. 45 kg (when all options are installed) Prohibited locations for installation . Areas where the unit will be exposed do direct sunlight or any other strong lights. . Dusty areas . Areas subject to vibration. .
1-3. Installation Space (External dimensions) 1-3. Installation Space (External dimensions) 279.4 354(8U) 339 482 465 440 37.6 35 7 520 1-3-1. MVS8000SF-C 17.5 375 144.5 61 115.5 370 115.
1-4. Installing the Options 1-4. Installing the Options Model name The MVS8000SF-C is shipped from the factory with the necessary option boards (refer to the following table) already installed in accordance with the specified system configuration. The following options are available for the MVS-8000SF.
1-4. Installing the Options Installation Procedure 1. Turn off the main power of the MVS-8000SF and disconnect the AC power cord from the wall outlet. 2. Loosen the four screws (with drop-safe) and remove the front panel to the arrow. 4. While the eject levers are opened as shown in the illustration, insert the plug-in board into the board guide rail. Screws (with drop-safe) Front panel Screws (with drop-safe) 3. Remove the six screws and remove the plug-in board loose-proof assembly.
1-4. Installing the Options Name of option Name of board Slot on the front side MKS-8210HD/SD/M*1 DO-41/DO-42/ DO-44 board 3, 8 MIX-45 board 4, 9 KPC-16 board 5, 10 DI-40/DI-41/ DI-43 board 6, 11 DIF-119/DIF-122/ DIF-141 board 7 MKS-8170HD/SD/M MKS-8420M CC-90 board 12 MKS-8160HD/SD/M*2 OUT-23/OUT-24/ OUT-27 board 14 , 15 MKS-8440HD/SD/M DIO-62/DIO-63/ DIO-74 board 16 MY-102 board 17 5. While closing the eject levers in the direction of arrow 1, push in the plug-in board.
1-4. Installing the Options 1-4-2. Installing the Connector Board 2. Insert the connector board horizontally level and secure it with the two fixing screws. 1. Remove the two screws and remove the blank panel. n To install the connector board into the slot in which the other board is installed already, loosen the two fixing screws and remove the connector board that is installed already.
1-4. Installing the Options 1-4-3. Installing the HK-PSU04 The HK-PSU04 is used after it is installed in the MVS8000SF. n Before installing the HK-PSU04, be sure to turn off the main power. If the HK-PSU04 is installed while the main power is turned on, it can result in electrical shock or damage to printed circuit boards. Installation procedure 1. Remove the front panel of the MVS-8000SF. (Refer to Section 1-4-1.) 2.
1-4. Installing the Options 1-4-5. Installing the MKS-8420M c Be sure to turn off the POWER switch before starting installation work. If installation work is started with the POWER switch left on, it may cause electrical shock or damage to printed circuit boards. MKS-8420M consists of the following boards. . CC-90 board : 1 piece . CPU-DK module : 3 pieces CC-90 board installation Refer to “1-4-1. Installing the Plug-in Boards”.
1-5. Rack Mounting 1-5. Rack Mounting 2. Rack Mounting Procedure The MVS-8000SF is mounted in the 19-inch standard rack. To mount the MVS-8000SF in the rack, use the specified rack mount kit and follow the procedure described below. This section describes the rack mounting procedure using the RMM-10 rack mount kit. Specified rack mount kit : RMM-10 n If other than the specified rack mount kit is used, the unit may not be mounted in the 19-inch standard rack. Parts of the RMM-10 . Rack tool .
1-5. Rack Mounting 2. Loosen the screws on the rear of the right and left adapters and adjust the length of the adapter according to the depth of the rack. (The illustration below shows the left adapter.) 6. Align the groove of the rack tool at the side of the equipment with the rail, and slide the equipment to the rear. n The rack tools are hooked on the rails as shown below.
1-6. Matching Connectors 1-6. Matching Connectors Use the following connectors, cables or equivalents when connecting cables to the unit. Model name Panel indication MKS-8110SD/HD/M PRIMARY INPUTS 1 to 17 MKS-8160SD/HD/M OUTPUTS 1 to 8 Connector name Matching connector and cable BNC, 75 Z Name Sony part No.
1-7. Input/Output Signals of Connectors 1-7. Input/Output Signals of Connectors The input/output signals of the connectors at the rear panel are as follows. TERMINAL : RS-232C (D-sub 9-pin, Female) to Terminal 1 5 9 6 _ EXT VIEW _ Pin No.
1-7. Input/Output Signals of Connectors REMOTE 1 to 4 : RS-422A (D-sub 9-pin, Female) (*5) from External Devices 1 5 9 6 _ EXT VIEW _ Pin No. Signal Name Function 1 FG Frame ground 2 TX_ Transmitted data (_) 3 RX+ Received data (+) 4 GND Common ground 5 _ No Connection 6 GND Common ground 7 TX+ Transmitted data (+) 8 RX_ Received data (_) 9 _ No Connection (*5) : Controlling equipment DATA/CTRL : 100BASE-TX, RJ-45 (8-pin) 1 8 _ EXT VIEW _ Pin No.
1-8. Checks on Completion of Installation 1-8. Checks on Completion of Installation 1-8-1. Description of On-board Switches and LEDs n The number shown in the parentheses ( ) indicated the address on the circuit board. 1.
1-8. Checks on Completion of Installation D802 (A-2) : COM2 100 status LED COM CPU-2 Ethernet communication speed status indication. Lit : 100 Mb/s Not lit : 10 Mb/s D901 (A-2) : REF EXT status LED REF IN signal presence/absence status indication. Lit when the REF signal is input to the REF IN connector. Not lit when the REF signal is not input to the REF IN connector. D902 (A-2) : PLL LOCK status LED REF IN signal format status indication. Lit when the REF IN signal matches with the switcher format setup.
1-8. Checks on Completion of Installation CN503 (A-5) : TERMINAL pin This pin is connected to the COM CPU-1 control terminal and used during maintenance. Conforms to RS-232C. : Main CPU D10 (green) (A-1) : RUN status LED RUN status indication. Lit when the CPU-DR module starts operating. CN703 (A-5) : TERMINAL pin This pin is connected to the COM CPU-2 control terminal and used during maintenance. Conforms to RS-232C.
1-8. Checks on Completion of Installation DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) : STATUS1 to STATUS4 LED Used for maintenance purpose. Only the STATUS1 LED is lit in normal operation. DI4 (green) (B-5) : +3.3 V Indicates the status of the VCC (CORE) and VCC (I/O) powers that are supplied to the CPU-DK module. D100 (B-1) : REF OK status LED Lit while V sync of the reference input is detected.
1-8. Checks on Completion of Installation 2.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 E6 TP6002 TP4002 TP6001 TP4001 3 D1 TP2 D6 4 TP1 D7 TP3 E2 E1 TP6000 TP4500 TP4000 5 D9 D8 TP4 E3 6 CN1 7 S1 8 TP1000 E4 TP1500 TP2000 E5 TP2500 TP3000 TP2002 TP2502 TP3500 9 TP1502 TP1002 TP1001 TP1501 10 TP2001 TP2501 TP3001 E7 TP3502 TP3002 TP3501 11 TP9 TP8 TP7 TP5 13 TP6 12 DO-42 board A side/Component side .
1-8. Checks on Completion of Installation E1 (F-6), E2 (J-4), E3 (L-6), E4 (E-9), E5 (J-9), E-6 (M-12), E-7 (N-9), E-8 (A-9) : GND terminal (DO-41 board) Use this terminal as the earth point for measuring the respective check terminals. TP1000 (E-9), TP1500 (F-9), TP2000 (G-9), TP2500 (J-9), TP3000 (K-9), TP3500 (M-9), TP4000 (K-4), TP4500 (J-4), TP6000 (H-4) : PLL LOCK signal check terminal (DO-41 board) PLL-LOCK signal measuring terminal.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 D1 3 TP1 D9504 TP9501 E2 4 D9004 TP9001 D5 E8 5 E1 TP4 E3 6 7 S2 8 9 E4 E5 CN1 S1 E7 10 11 E6 12 TP5 13 TP8 TP9 DO-44 board A side/Component side . DO-44 board D1 (A-3) : +12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-4) : CONF ERR status LED FPGA (EP20K100E) CONFIG DONE status indication.
1-8. Checks on Completion of Installation TP1 (A-3) : +12 V check terminal +12 V measuring terminal. TP4 (H-6), TP5 (H-13), TP9 (N-13) : CK (clock for video signal) signal check terminal Used when checking the clock for video signal. TP8 (M-13) : HD (horizontal sync) signal check terminal Used when checking the HD signal supplied from the mother board. TP9001 (A-4) : +1.8 V check terminal +1.8 V measuring terminal. TP9501 (A-4) : +3.3 V check terminal +3.3 V measuring terminal.
1-8. Checks on Completion of Installation 3.
1-8. Checks on Completion of Installation D3701 (A-5) : +2.5 V +2.5 V power supply status indication. Lit when the +2.5 V power is supplied. TP3603 (N-12) : CKX (control timing) signal check terminal Use this terminal to check the CKX signal supplied from mother board. D3702 (A-4) : +3.3 V +3.3 V power supply status indication. Lit when the +3.3 V power is supplied. TP3604 (N-12) : VD (vertical sync) signal check terminal Use this terminal to check the VD signal supplied from mother board.
1-8. Checks on Completion of Installation 4. KPC-16 board (MKS-8210HD/SD/M) A B C D E F G 1 H J K L M N E6064 P R TP6067 2 TP6060 3 TP6061 4 E6066 E6069 TP6068 D6001 D6065 5 D6060 D6062 D6063 D6061 6 CN6000 E6063 7 TP6000 8 D6108 D6107 9 D6106 D6105 D6104 D6103 D6102 10 D6101 D6100 D6109 E6065 TP6801 TP6802 11 12 E6062 TP6800 13 TP6104 TP6103 TP6102 TP6101 A side/Component side D6001 (A-5) : RESET status LED System reset status indication. Lit when the +3.
1-8. Checks on Completion of Installation D6103 (A-10) : WASH2 FPGA CONFIG DONE status LED WASH2 FPGA CONFIG DONE status indication. Not lit when configuration is completed. D6104 (A-9) : WASH1 FPGA CONFIG DONE status LED WASH1 FPGA CONFIG DONE status indication. Not lit when configuration is completed. D6105 (A-9) : KEYER4 FPGA CONFIG DONE status LED KEYER4 FPGA CONFIG DONE status indication. Not lit when configuration is completed.
1-8. Checks on Completion of Installation 5.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 TP3001 TP3501 E2 TP4501 TP5001 TP5501 TP4001 3 D1 TP3 D2 TP1 4 D3 TP2 E1 D5 5 D6 TP3000 TP3500 TP4000 TP4500 TP5000 TP5500 TP7000 TP7500 TP6500 TP6000 CN1 6 S1 E3 7 8 E6 TP2000 TP2500 TP2501 TP1001 TP1000 TP1500 9 10 TP1501 TP7001 TP7501 TP6501 TP6001 TP2001 TP204 13 E7 TP203 12 E5 TP202 E4 TP201 11 DI-41 board A side/Component side .
1-8. Checks on Completion of Installation E1 (A-4), E2 (J-2), E3 (F-6), E4 (D-11), E5 (H-11), E6 (N-8), E7 (L-12) : GND terminal (DI-41 board) Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-4) : +3.3 V check terminal +3.3 V measuring terminal. TP2 (A-4) : +2.5 V check terminal +2.5 V measuring terminal. TP3 (A-3) : +12 V check terminal +12 V measuring terminal. TP201 (N-13) : VD (vertical sync) signal check terminal VD signal measuring terminal.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 E2 D1 3 4 E3 TP1 D9551 TP9501 5 D9051 E1 TP3001 TP3501 TP8001 TP4001 TP4501 TP9001 TP5001 TP5501 D401 6 E7 7 S1 S101 8 CN101 TP2001 TP2501 TP1001 TP1501 TP7001 TP7501 TP6501 TP6001 9 E6 10 11 12 13 DI-43 board A side/Component side . DI-43 board D1 (A-3) : +12 V +12 V power supply status indication. Lit when the +12 V power is supplied.
1-8. Checks on Completion of Installation TP1 (A-3) : +12 V check terminal +12 V measuring terminal. TP501 (P-13) : HD (horizontal sync) signal check terminal HD signal measuring terminal. TP1001 (D-8), TP1501 (E-8), TP2001 (A-8), TP2501 (C-8), TP3001 (D-5), TP3501 (F-5), TP4001 (H-5), TP4501 (K-5), TP5001 (L-5), TP5501 (N-5), TP6001 (L-8), TP6501 (K-8), TP7001 (G-8), TP7501 (H-8), TP8001 (G-5) : ERR check terminal SDI signal error measuring terminal. TP9001 (A-5) : +1.8 V check terminal +1.
1-8. Checks on Completion of Installation 6.
1-8.
1-8. Checks on Completion of Installation S2300 (A-9) : RESET switch Pressing this switch resets the DIF-119 and 122 board. TP1304 (G-12) : CRC signal check terminal (DIF119 board) CRC signal measuring terminal. S2301 (A-5) : MONITOR reset switch The reset switch that is used to reset the monitor in the maintenance from the TERMINAL. TP1305 (G-12) : SIGDET signal check terminal (DIF-119 board) SIGDET signal measuring terminal.
1-8. Checks on Completion of Installation TP3308 (L-12) : CK (clock for video signal) signal (DIF-119 board) Uses this terminal when checking the clock signal for video. TP3401 (A-4) : +12 V check terminal (DIF-122 board) +12 V measuring terminal. TP3309 (H-5) : CK2 signal check terminal (DIF-119 board) Uses this terminal when checking the clock signal for video. TP3402 (A-4) : +3.3 V check terminal (DIF-122 board) +3.3 V measuring terminal.
1-8.
1-8. Checks on Completion of Installation S2700 (A-7) : JTAG switch Used only for production in the assembly factory. Set this switch to ON only when writing program in the JTAG device with ISP. CN2301 (A-6) : TERMINAL pin This pin is connected to the CPU control terminal and used during maintenance. Conforms to RS-232C. CN2700 (A-6) : ISP common connector Used only for production in the assembly factory. Used for program writing into the JTAG device with ISP.
1-8. Checks on Completion of Installation 7. XPT-21 board (MVS-8000SF) A B C D E F G H J K L M N P R 1 2 TP2 3 TP1 4 E10 E7 CN3301 D3401 5 D2 E1 D3 D4 6 CN3303 7 E9 CN3001 E8 8 E2 S3401 9 A S3301 B DI1 10 DI4 CN3901 SW2 11 CPU-DK Module C E5 D TP3401 SW1 E E3 D8 D7 D6 D3 D2 12 5 4 3 F 2 1 13 E6 TP3004 E4 TP3001 TP3005 TP3003 TP3002 A side/Component side D3401 (A-5) : RESET status LED System reset status indication.
1-8. Checks on Completion of Installation CN3303 (A-6) : DEBUG terminal Not used. This terminal conforms to RS-232C. (C-10) Refer to < LED on the CPU DK module > in “1. CA-44 board”. CN3901 (A-11) : IEEE1394 terminal Not used. This terminal conforms to IEEE1394. (C-10) Refer to < Switch on the CPU DK module > in “1. CA-44 board”.
1-8. Checks on Completion of Installation 8.
1-8.
1-8. Checks on Completion of Installation S100 (A-3) : OUT-CPU RESET switch Pressing this switch initializes the CPU on the OUT-23/24 board. S1501 (A-7) : MONITOR reset switch The reset switch that is used to reset the monitor during maintenance through the terminal. CN1400 (A-5) : ISP common connector Used only for production in the assembly factory. Used for program writing into the JTAG device with ISP.
1-8. Checks on Completion of Installation TP604 (N-12), TP1004 (N-5) : CRC signal check terminal (OUT-23 board) CRC signal measuring terminal. TP605 (N-11), TP1005 (N-5) : SIG_DET signal check terminal (OUT-23 board) SIG_DET signal measuring terminal. TP606 (N-8), TP706 (L-9), TP806 (J-9), TP906 (G-9), TP1006 (N-2), TP1106 (L-2), TP1206 (J-2), TP1306 (F-2) : PLL_LOCK signal check terminal (OUT-23 board) PLL_LOCK signal measuring terminal.
1-8. Checks on Completion of Installation A B C D E F G H 1 J K L M N E5 P E2 2 3 4 S1 D1 TP1 D9504 D9004 TP9001 TP9501 TP700 D1600 S1600 E1 5 TP702 CN1400 E3 TP701 TP1500 TP1400 TP1300 TP1200 TP1000 TP900 TP800 6 7 8 E6 S2100 CN1902 D702 D701 D700 TP2100 A 9 DI4 10 B DI1 SW2 CPU-DK Module* C D SW1 E D8 D7 D6 D3 D2 11 12 5 4 3 TP1100 F 2 1 TP202 E7 TP205 TP203 TP204 * : The CPU-DK module is installed only in the OUT-27 board of slot 14.
1-8. Checks on Completion of Installation CN1600 (A-5) : ISP common connector Used only for production in the assembly factory. Used for program writing into the JTAG device with ISP. CN1902 (A-7) : TERMINAL pin This pin is connected to the control terminal and used during maintenance. E1 (A-5), E2 (N-1), E3 (N-5), E4 (N-12), E5 (J-1), E6 (G-7), E7 (G-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals.
1-8. Checks on Completion of Installation 9.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 TP2000 TP2500 TP3000 TP3500 E1 D1 3 TP2 D6 E5 TP1 4 D7 TP3 TP2501 TP2001 TP2002 5 E6 TP2502 TP3501 TP3502 TP3001 TP3002 D100 D101 6 CN1 TP4 E4 TP4000 7 E2 TP4500 TP5000 TP5500 S1 8 TP1001 TP1501 9 TP5501 10 TP4001 TP1000 TP1500 TP4002 TP4501 TP4502 TP5001 TP5002 TP5502 E3 12 TP7 TP8 TP9 TP10 11 E7 TP6 TP5 13 DIO-63 board A side/Component side .
1-8. Checks on Completion of Installation E1 (N-3), E2 (P-6), E3 (P-11), E4 (H-6), E5 (F-3), E6 (A-8), E7 (E-12) : GND terminal (DIO-62 board) Use this terminal as the earth point for measuring the respective check terminals. E1 (N-2), E2 (P-6), E3 (P-10), E4 (H-6), E5 (F-3), E6 (A-5), E7 (A-12) : GND terminal (DIO-63 board) Use this terminal as the earth point for measuring the respective check terminals.
1-8. Checks on Completion of Installation TP2000 (H-2), TP2500 (K-2), TP3000 (L-3), TP3500 (N-3), TP4000 (L-3), TP4500 (K-8), TP5000 (L-8), TP5500 (N-8) : PLL_LOCK signal check terminal (DIO-62 board) PLL_LOCK signal measuring terminal. TP1000 (D-11), TP1500 (E-11), TP2000 (G-2), TP2500 (J-2), TP3000 (K-2), TP3500 (M-2), TP4000 (G-7), TP4500 (J-7), TP5000 (K-7), TP5500 (M-7) : VCO_FRQ signal check terminal (DIO-63 board) VCO_FRQ signal measuring terminal.
1-8. Checks on Completion of Installation A B C D E F G H J K L M N P R 1 2 E1 D1 3 TP1 D3 TP9501 D2 4 TP9001 D501 E5 5 E6 6 E4 TP102 E2 7 S601 8 CN601 9 S1 10 TP1001 TP1501 E3 12 13 TP201 TP202 TP203 TP204 11 E7 TP104 TP101 TP103 DIO-74 board A side/Component side . DIO-74 board D1 (A-3) : +12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. D2 (A-4) : +1.8 V +1.
1-8. Checks on Completion of Installation E1 (N-2), E2 (P-6), E3 (P-10), E4 (H-6), E5 (F-3), E6 (A-5), E7 (C-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-3) : +12 V check terminal +12 V measuring terminal. TP101 (P-12), TP102 (J-6), TP103 (J-13), TP104 (D-13) : CK (clock for video) signal check terminal Uses this terminal when checking the clock signal for video.
1-8. Checks on Completion of Installation 10.
1-8. Checks on Completion of Installation E121 (P-8), E122 (P-10), E123 (P-3), E124 (P-4), E129 (P-11), E130 (P-9), E131 (P-4), E132 (P-5), E508 (E-12), E601 (D-7), E801 (N-7), E1001 (N-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals. TP203 (C-3) : +3.3 V check terminal +3.3 V measuring terminal. TP204 (C-5) : +1.8 V check terminal +1.8 V measuring terminal.
1-8. Checks on Completion of Installation 11.
1-8. Checks on Completion of Installation S2001 (A-5) : JTAG switch Used only for production in the assembly factory. Set this switch to ON only when writing program in the JTAG device with ISP. S101 (A-8) : CC-CPU reset switch Pressing this switch initializes the CPU on the CC-90 board. S400 (A-8) : Monitor reset switch The reset switch that is used to reset the monitor during maintenance through the terminal.
1-8. Checks on Completion of Installation 12.
1-8. Checks on Completion of Installation 1-8-2. Checks on the Switch Setting the Number of Power Supply Units Before turning on the power of the MVS-8000SF, confirm that the switch S303 on the CA-44 board is set in the following position (default setting).
1-9. System Connection 1-9. System Connection Configure the MVS-8000 system connections referring to the connection example as shown below. 1.
1-9. System Connection 2.
Section 2 Service Overview 2-1. Troubleshooting The main power of the MVS-8000 cannot be turned on. (Indicator does not light green.) The monitor picture is not displayed correctly. A picture is not displayed on the monitor screen even though the main power of the MVS-8000SF is turned on. The main power of the MVS-8000SF cannot be turned on. (Indicator does not light green.) Are two or more power NO switches of the MVS-8000SF turned on? Set two or more power switches of the MVS-8000SF to on.
2-2. Periodic Inspection and Maintenance 2-3. About the Data Backup Capacitor 2-2. Periodic Inspection and Maintenance 2-2-1. Cleaning 1. Front panel The filter on the rear of the front panel can easily accumulate the dust. Be sure to remove dust by cleaning as follows. (1) Remove the front panel. (Refer to Section 1-4-1.) (2) Remove the dust accumulated on the filter with a vacuum cleaner. n Cleaning the filter by washing in water is recommended when there is a heavy accumulation of dust.
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation.
MVS8000SF-C (SY) E 3-620-565-03 Sony Corporation B&P Company Printed in Japan 2003.