User Manual

124
BLACK
GAMMA
Corrects gamma in low intensity areas.
[BLACK GAMMA] is disabled when [GAMMA] is set to [HLG], [HLG1],
[HLG2], or [HLG3].
RANGE HIGH,
MIDDLE,
LOW
Selects the correction range.
LEVEL –7 (maximum
black
compression)
to +7
(maximum
black stretch)
Sets the correction level.
KNEE MODE AUTO,
MANUAL
Selects the mode.
AUTO: Sets the knee point and
slope automatically.
MANUAL: Sets the knee point
and slope manually.
AUTO SET Settings when [AUTO] is selected.
MAX POINT 90% to 100% MAX POINT: Sets the
maximum value of the knee
point.
SENSITIVITY HIGH,
MIDDLE,
LOW
SENSITIVITY: Sets the
sensitivity.
MANUAL
SET
Settings when [MANUAL] is selected.
POINT 75% to 105% POINT: Sets the knee point.
SLOPE –5 (gentle) to
+5 (steep)
SLOPE: Sets the knee slope.
[KNEE] is disabled when set to
+5.
Item Sub-items Settings Description
Menu items (Continued)